55
Control Head Setup
6. Calibrate Your MEGA Live Imaging TargetLock Heading Sensor
Use the following instructions to calibrate your MEGA Live Imaging TargetLock
Heading Sensor. Before beginning calibration, your control head must be paired
with your TargetLock Heading Sensor and your MEGA Live Imaging transducer must
be in the water and connected to your control head.
NOTE:
Your transducer will rotate during calibration. Ensure that your
transducer cables can move freely before beginning this procedure. Your
transducer will return to its original position when calibration is complete.
APEX/SOLIX Series
1. Press the HOME key.
2. Select Settings > CHIRP Sonar > MEGA Live > Calibrate TargetLock Heading
Sensor.
3. Your MEGA Live Imaging TargetLock will begin calibration. A message will
display on your control head when calibration is complete.
HELIX Series
1.
Main Menu:
On your control head, press the MENU key twice.
2. Select the Accessories tab > MEGA Live > MEGA Live Installation.
3. Select Calibrate TL Heading Sensor, and press the RIGHT cursor key.
4. Your MEGA Live Imaging TargetLock will begin calibration. A message will
display on your control head when calibration is complete.
Содержание MEGA Live
Страница 1: ...1 MEGA LIVE IMAGING TARGETLOCK INSTALLATION GUIDE 532889 3EN_A ...
Страница 6: ...iii ...
Страница 22: ...16 MEGA Live Installation Connecting the Cable Cover The molded anchor point is keyed ...
Страница 24: ...18 MEGA Live Installation MEGA Live Views Forward View Down View Landscape Mode ...
Страница 55: ...49 Control Head Setup Forward Landscape ...
Страница 74: ...68 Notes ...