Maintenance Window
The maintenance window name if the task is configured to run during a maintenance window.
Start time
The task start date and time (UTC).
• If a time window is specified, the start time is listed.
• If a maintenance window is selected, the maintenance window start time is listed.
• If a start time is not specified and the task state is
Complete, Expired, or Exception, the value N/A is displayed.
• If a start time is not specified and the task state is
InProgress or Pending:
◦
The value
Immediately after the associated updater checks is displayed when the task is first in the queue.
◦
The value
After previous tasks are executed is displayed if the task is not first in the queue.
Expiration
The task expiration date and time (UTC).
If a maintenance window is selected, the maintenance window end time is listed.
Update Recovery Set?
This value is displayed only when a component is selected. A value of
Yes means that the queued component will replace
the component in the System Recovery Set after the task is initiated and completed successfully.
Created by user with Recovery Set privilege?
This value is displayed only when a component is selected. A value of
Yes indicates that the task was created by a user
with the Recovery Set privilege.
This privilege is required for making an optional update to the System Recovery Set after a queued update is completed
successfully.
This privilege is also required for firmware downgrades when the
Downgrade Policy is set to the Downgrade requires
Recovery Set privilege option.
Managing the server power
The
Virtual Power Button section on the Server Power page displays the current power state of the server, as well as options
for remotely controlling server power.
System Power indicates the state of the server power when the page is first opened.
The server power state can be
ON, OFF, or Reset. Use the browser refresh feature to view the current server power state. The
server is rarely in the
Reset state.
Prerequisites
Virtual Power and Reset privilege
Procedure
1. Click Power & Thermal in the navigation tree.
The page opens with the
Server Power tab selected.
2. Click one of the following buttons:
96 Using HPE iLO 5
Содержание ProLiant e910
Страница 148: ...148 Customer self repair...
Страница 149: ...Customer self repair 149...
Страница 150: ...150 Customer self repair...
Страница 158: ...c Remove the PCIe riser board Right PCIe riser board Left PCIe riser board 158 Removal and replacement procedures...
Страница 182: ...UID unit identification UEFI Unified Extensible Firmware Interface 182 Acronyms and abbreviations...