Chassis Manager. When the port is disabled, the Edgeline EL8000 Chassis Manager web interface will show the ProLiant e910
Server Blade as failed. No options to control the ProLiant e910 Server Blade will be active or able to show status messages.
iLO setup with the iLO 5 Configuration Utility
Hewlett Packard Enterprise recommends using the iLO 5 Configuration Utility to set up iLO for the first time and to configure
iLO network parameters for environments that do not use DHCP, DNS, or WINS.
Configuring a static IP address (iLO 5 Configuration Utility)
This step is required only if you want to use a static IP address. When you use dynamic IP addressing, the DHCP server
automatically assigns an IP address for iLO.
To simplify installation, Hewlett Packard Enterprise recommends using DNS or DHCP with iLO.
Procedure
1.
(Optional) If you access the server remotely, start an iLO remote console session.
2.
Restart or power on the server.
3.
Press
F9 in the server POST screen.
The UEFI System Utilities start.
4.
Click
System Configuration.
5.
Click
iLO 5 Configuration Utility.
6.
Disable DHCP:
a. Click Network Options.
b. Select OFF in the DHCP Enable menu.
The
IP Address, Subnet Mask, and Gateway IP Address boxes become editable. When DHCP Enable is set to ON,
you cannot edit these values.
7.
Enter values in the
IP Address, Subnet Mask, and Gateway IP Address boxes.
8.
To save the changes and exit, press
F12.
The iLO 5 Configuration Utility prompts you to confirm that you want to save the pending configuration changes.
9.
To save and exit, click
Yes - Save Changes.
The iLO 5 Configuration Utility notifies you that iLO must be reset in order for the changes to take effect.
10. Click OK.
iLO resets, and the iLO session is automatically ended. You can reconnect in approximately 30 seconds.
11. Resume the normal boot process:
a. Start the iLO remote console.
The iLO 5 Configuration Utility is still open from the previous session.
b. Press ESC several times to navigate to the System Configuration page.
c. To exit the System Utilities and resume the normal boot process, click Exit and resume system boot.
56 Setting up iLO
Содержание ProLiant e910
Страница 148: ...148 Customer self repair...
Страница 149: ...Customer self repair 149...
Страница 150: ...150 Customer self repair...
Страница 158: ...c Remove the PCIe riser board Right PCIe riser board Left PCIe riser board 158 Removal and replacement procedures...
Страница 182: ...UID unit identification UEFI Unified Extensible Firmware Interface 182 Acronyms and abbreviations...