Storage controller options
The server supports the following storage controllers:
• For SATA drives only – Embedded HPE Smart Array S100i SR Gen10 Controller
• For SAS and SATA drives – HPE Smart Array type-p controller
The Smart Array type-p controller options are supported in both the primary and secondary riser slots.
IMPORTANT:
The Apollo DX2800 Gen10 Chassis with 16 NVMe drives does not support
connection to the embedded Smart Array S100i SR Gen10 Software RAID nor to a Smart Array
type-p controller.
Installing a Smart Array type-p controller in the primary riser cage
CAUTION:
The maximum inlet ambient temperature for most components installed in the system is
35°C (95°F). Some components, however, are subject to thermal limitations depending on the
chassis model and the fan configuration. There are some hardware configurations where it is
necessary to limit the number of drives installed in the chassis. For more information, see
.