9.
Using the SPP,
:
• System ROM
• Storage controller
• Network controller
Set up the storage
10.
Set up the storage. Do one of the following:
• To configure the server to boot from a SAN, see the following guide:
https://www.hpe.com/info/boot-from-san-config-guide
• If an HPE Smart Array SR controller is installed, use the HPE Smart Storage Administrator to
create arrays:
a.
From the boot screen, press
F10
to run Intelligent Provisioning.
b.
From Intelligent Provisioning, run
HPE Smart Storage Administrator
.
• If no controller option is installed, do one of the following:
◦ AHCI is enabled by default. You can deploy an OS or virtualization software.
◦ Disable AHCI, enable software RAID, and then create an array:
a.
From the boot screen, press
F9
to run UEFI System Utilities.
b.
From the UEFI System Utilities screen, select
System Configurations
>
BIOS/Platform
Configuration (RBSU)
>
Storage Options
>
SATA Controller Options
>
Embedded
SATA Configuration
>
Smart Array SW RAID Support
.
c.
Enable
Smart Array SW RAID Support
.
d.
Save the configuration and reboot the server.
e.
Create an array:
I.
From the boot screen, press
F9
to run UEFI System Utilities.
II.
From the UEFI System Utilities screen, select
System Configuration
>
Embedded
Storage: HPE Smart Storage S100i SR Gen10
>
Array Configuration
>
Create
Array
.
Deploy an OS or virtualization software
11.
Manually deploy an OS or virtualization software:
a.
Insert the installation media.
For remote management, click
Virtual Drives
in the iLO remote console to mount images,
drivers, or files to a virtual folder. If a storage driver is required to install the OS, use the virtual
folder to store the driver.
b.
Press
F11
at boot screen to select the boot device.
c.
After the OS installed,
Register the server
12.
To experience quicker service and more efficient support, register the server at the HPE website:
36