An energy pack is supported only with Smart Array P-class controllers. Due to thermal concerns, HPE recommends
removing the energy pack if these controller type cards are not installed in the chassis.
The drive capacity must be less than 10 TB.
The drive capacity must be greater than or equal to 10 TB.
If the component is installed in server 1 or server 2, and the server is installed in the Apollo DX2200 Gen10 Chassis,
drive blanks must be installed in drive bays 1-2 and 2-2. Similarly, if the component is installed in server 3 or server 4,
and the server is installed in the Apollo DX2200 Gen10 Chassis, drive blanks must be installed in drive bays 3-2 and
4-2.
Fibre Channel and Converged Network adapters
Description
Chassis
Fan configuration
Number of drives
supported by the
server
Maximum inlet
ambient temperature
FC HBA
Apollo
DX2200
Gen10
Chassis
(12 LFF
backplane)
Redundant and
nonredundant
Not supported
Not supported
28°C (82.4°F)
Apollo
DX2600
Gen10
Chassis
(24 SFF or 16
SFF + 8
NVMe
backplane)
Redundant and
nonredundant
0 to 6 drives
25°C (77°F)
Apollo
DX2800
Gen10
Chassis
(24 SFF
backplane
with SAS
expander)
Redundant and
nonredundant
0 to 24 drives
25°C (77°F)
Apollo
DX2800
Gen10
Chassis
(16 NVMe
backplane)
Redundant and
nonredundant
0 to 4 drives
25°C (77°F)
CNA
Apollo
DX2200
Gen10
Chassis
Redundant and
nonredundant
Optical cable: Not
supported
Copper cable: 30°C
(86°F)
Table Continued
Specifications
123