The DIMM slots are structured to ensure proper installation. If you try to insert a DIMM but it does
not fit easily into the slot, you might have positioned it incorrectly. Reverse the orientation of the
DIMM and insert it again.
on page 22.
7. Install the server into the chassis
8.
Connect all peripheral cables to the server.
on page 19.
The installation is complete.
After installing the DIMMs, use the
System Utilities
>
System Configuration
>
BIOS/Platform
Configuration (RBSU)
>
Memory Options
to configure the memory settings.
Riser cage options
Installing the primary riser cage option
The primary riser function is linked to processor 1. This riser only supports low-profile expansion boards.
Prerequisites
Before installing this option, make sure that you have a T-15 Torx screwdriver available.
Procedure
1.
2.
Disconnect all peripheral cables from the server.
3.
Remove the server from the chassis
on page 19.
4.
on page 21.
5.
If a secondary riser option is installed,
.
6.
Do one of the following:
Hardware options installation
47