The DIMM slots are structured to ensure proper installation. If you try to insert a DIMM but it does
not fit easily into the slot, you might have positioned it incorrectly. Reverse the orientation of the
DIMM and insert it again.

6. Install the air baffle

 on page 22.

7. Install the server into the chassis

 on page 20.

8.

Connect all peripheral cables to the server.

9. Power up the server

 on page 19.

The installation is complete.

After installing the DIMMs, use the 

System Utilities

 > 

System Configuration

 > 

BIOS/Platform

Configuration (RBSU)

 > 

Memory Options

 to configure the memory settings.

Riser cage options

Installing the primary riser cage option

The primary riser function is linked to processor 1. This riser only supports low-profile expansion boards.

Prerequisites

Before installing this option, make sure that you have a T-15 Torx screwdriver available.

Procedure

1.

Power down the server

 on page 19.

2.

Disconnect all peripheral cables from the server.

3.

Remove the server from the chassis

 on page 19.

4.

Remove the air baffle

 on page 21.

5.

If a secondary riser option is installed, 

remove the bayonet board

.

6.

Do one of the following:

Hardware options installation

47

Содержание ProLiant DX170r Gen10

Страница 1: ...dition 1 Abstract This document is for the person who installs administers and troubleshoots servers and storage systems Hewlett Packard Enterprise assumes you are qualified in the servicing of comput...

Страница 2: ...e U S Government under vendor s standard commercial license Links to third party websites take you outside the Hewlett Packard Enterprise website Hewlett Packard Enterprise has no control over and is...

Страница 3: ...server 19 Power down the server 19 Remove the server from the chassis 19 Install the server into the chassis 20 Remove the air baffle 21 Install the air baffle 22 Remove the bayonet board 22 Remove t...

Страница 4: ...riser cage option 48 Expansion board options 49 Installing an expansion board in the primary riser cage 49 Installing an expansion board in the secondary riser cage 52 Storage controller options 54 I...

Страница 5: ...cure Boot 89 Launching the Embedded UEFI Shell 89 HPE Smart Storage Administrator 90 HPE MR Storage Administrator 91 HPE InfoSight for servers 91 StorCLI 91 USB support 92 External USB functionality 9...

Страница 6: ...requirements 103 Thermal limitations for components in systems with the Enhanced Processor Performance feature enabled 103 Thermal limitations for components in systems with the Enhanced Processor Per...

Страница 7: ...th 24 SFF drives HPE Apollo DX2600 Gen10 Chassis with 16 SFF 8 NVMe drives HPE Apollo DX2800 Gen10 Chassis with 16 NVMe drives HPE Apollo DX2800 Gen10 Chassis with 24 SFF drives Server nodes HPE ProLi...

Страница 8: ...ly disabled 2 The Media Module adapter is a hardware option Serial number iLO information pull tab The serial number iLO information pull tab is double sided One side shows the server serial number an...

Страница 9: ...k activity 3 Health LED1 Solid green Normal Flashing green iLO is rebooting Flashing amber System degraded Flashing red System critical 4 Do not remove LED Flashing white Do not remove the server Remo...

Страница 10: ...cility power is not present power cord is not attached no power supplies are installed power supply failure has occurred or the front I O cable is disconnected Server UID LED The UID LED is used to lo...

Страница 11: ...scription 1 Primary PCIe x16 riser connector 1 2 Media Module connector 3 System battery 4 OPA adapter sideband cable connector 5 M 2 SSD riser connector 6 Processor 1 7 DIMM slots for processor 1 8 P...

Страница 12: ...0 Reserved S11 Reserved S12 Reserved 1 To access the redundant ROM set S1 S5 and S6 to On 2 When the system maintenance switch position 6 is set to the On position the system is prepared to restore al...

Страница 13: ...B 128 GB 2 Rank 1R Single rank 2R Dual rank 4R Quad rank 8R Octal rank 3 Data width on DRAM x4 4 bit x8 8 bit x16 16 bit 4 Memory generation PC4 DDR4 5 Maximum memory speed 2133 MT s 2400 MT s 2666 MT...

Страница 14: ...L LRDIMM load reduced E Unbuffered ECC UDIMM For more information about product features specifications options configurations and compatibility see the HPE DDR4 SmartMemory QuickSpecs on the Hewlett...

Страница 15: ...s compatible with specific types of expansion options supported by the server The following riser options are supported Primary riser Secondary risers M 2 SSD riser Primary riser board components The...

Страница 16: ...ard components The server supports multiple riser options in the secondary position P1 secondary riser board components Item Slot number Description Supported options 1 Storage controller backup power...

Страница 17: ...roller backup power connector 2 2 PCIe3 x16 16 8 4 1 Smart Array type p controller Low profile expansion boards P1 P2 secondary riser port numbering FlexibleLOM riser board slot The FlexibleLOM riser...

Страница 18: ...M 2 SSD riser bay numbering The arrow points toward the server release lever Item Description 1 Bay 7 2 Bay 8 18 Component identification...

Страница 19: ...NT When the server is in standby mode auxiliary power is still being provided to the system To power down the server use one of the following methods Press and release the Power On Standby button This...

Страница 20: ...server from the chassis a Loosen the release lever thumbscrew b Open the release lever c Use the release lever to pull the server out of the chassis Install the server into the chassis CAUTION To avoi...

Страница 21: ...e CAUTION For proper cooling do not operate the server without the baffles expansion slot covers or blanks installed Procedure 1 Power down the server on page 19 2 Disconnect all peripheral cables fro...

Страница 22: ...ayonet board Prerequisites Before you perform this procedure make sure that you have a T 10 Torx screwdriver available Procedure 1 Power down the server on page 19 2 Disconnect all peripheral cables f...

Страница 23: ...b Remove the screws securing the cover to the server tray and then remove the cover c Disconnect the bayonet board cables and then remove the bayonet board Operations 23...

Страница 24: ...blank or riser cage is installed Prerequisites Before you perform this procedure make sure that you have a T 10 Torx screwdriver available Procedure 1 Power down the server on page 19 2 Disconnect al...

Страница 25: ...10 Torx screwdriver available Procedure 1 Install the bayonet board a Connect all the bayonet board cables b Install the bayonet board Make sure that the board is firmly seated in the connector c Inst...

Страница 26: ...erver into the chassis on page 20 4 Connect all peripheral cables to the server 5 Power up the server on page 19 Install the secondary riser blank Prerequisites Before you perform this procedure make...

Страница 27: ...form this procedure make sure that you have a T 10 Torx screwdriver available Procedure 1 Power down the server on page 19 2 Disconnect all peripheral cables from the server 3 Remove the server from t...

Страница 28: ...have a T 10 Torx screwdriver available Procedure 1 Install the secondary riser cage Make sure that the riser board is firmly seated in its system board connectors 2 Install the bayonet board on page 2...

Страница 29: ...down the server on page 19 2 Disconnect all peripheral cables from the server 3 Remove the server from the chassis on page 19 4 Remove the air baffle on page 21 5 If a secondary riser option is instal...

Страница 30: ...ry riser cage on page 28 3 If removed install the bayonet board 4 If removed install the bayonet board 5 Install the air baffle on page 22 6 Install the server into the chassis on page 20 7 Connect al...

Страница 31: ...nstalled remove the bayonet board 5 Do one of the following Remove the secondary riser blank on page 24 Remove the secondary riser cage on page 27 6 Remove the primary riser blank Install the primary...

Страница 32: ...riser blank on page 26 Install the secondary riser cage on page 28 3 If removed install the bayonet board 4 Install the server into the chassis on page 20 5 Connect all peripheral cables to the server...

Страница 33: ...undation Care Keep systems running 6 Hour Call to Repair1 4 Hour 24x7 Next Business Day Proactive Care Help prevent service incidents and get you to technical experts when there is one 6 Hour Call to...

Страница 34: ...mutually scheduled time convenient to your organization Allows your IT resources to stay focused on their core tasks and priorities Full coverage during the warranty period for products that require...

Страница 35: ...se Remotely Connect to the iLO web interface and run a remote console a Verify the following iLO is licensed to use the remote console feature If iLO is not licensed visit the HPE website http www hpe...

Страница 36: ...figurations BIOS Platform Configuration RBSU Storage Options SATA Controller Options Embedded SATA Configuration Smart Array SW RAID Support c Enable Smart Array SW RAID Support d Save the configurati...

Страница 37: ...om the cabinet CAUTION To prevent improper cooling and damage to the equipment do not block the ventilation openings When vertical space in the rack is not filled by a server or rack component the gap...

Страница 38: ...ower fluctuations and temporary interruptions with a regulating UPS This device protects the hardware from damage caused by power surges and voltage spikes and keeps the server in operation during a p...

Страница 39: ...CAUTION Protect the server from power fluctuations and temporary interruptions with a regulating UPS This device protects the hardware from damage caused by power surges and voltage spikes and keeps t...

Страница 40: ...ling electrostatic sensitive parts Use a wrist strap connected by a ground cord to a grounded workstation or computer chassis Wrist straps are flexible straps with a minimum of 1 megohm 10 percent res...

Страница 41: ...event damage to electrical components properly ground the server before beginning any installation procedure Improper grounding can cause electrostatic discharge SUV cable option CAUTION To avoid equi...

Страница 42: ...ctor 3 Connect a USB hub to the USB connector 4 Connect a USB mouse to the USB hub 5 Connect a USB keyboard to the USB hub 6 Connect a USB key or a USB optical drive to the USB hub Processor heatsink...

Страница 43: ...rs at this time For more information see the product QuickSpecs on the Hewlett Packard Enterprise website http www hpe com info qs Install the processor heatsink assembly CAUTION The maximum inlet amb...

Страница 44: ...and gently lower it down until it sits evenly on the socket The heatsink alignment posts are keyed The processor will only install one way Your heatsink might look different than the one shown CAUTION...

Страница 45: ...e F9 key to access System Utilities 2 From the System Utilities screen select System Configuration BIOS Platform Configuration RBSU Advanced Options Fan and Thermal Options Thermal Configuration 3 Sel...

Страница 46: ...er all DDR4 2666 DIMMs or all DDR4 2933 DIMMs in the server HPE SmartMemory speed information For more information about memory speed information see the Hewlett Packard Enterprise website https www h...

Страница 47: ...stem Configuration BIOS Platform Configuration RBSU Memory Options to configure the memory settings Riser cage options Installing the primary riser cage option The primary riser function is linked to...

Страница 48: ...er cage on page 28 10 If removed install the bayonet board 11 Install the air baffle on page 22 12 Install the server into the chassis on page 20 13 Connect all peripheral cables to the server 14 Powe...

Страница 49: ...s complete Expansion board options Installing an expansion board in the primary riser cage The primary riser slot only supports low profile expansion boards For more information on this riser option s...

Страница 50: ...option is installed remove the bayonet board 6 Do one of the following Remove the secondary riser blank on page 24 Remove the secondary riser cage on page 27 7 Remove the secondary riser cage on page...

Страница 51: ...ith the option 13 Install the expansion board Make sure that the board is firmly seated in the slot 14 Install the primary riser cage on page 30 15 Do one of the following Install the secondary riser...

Страница 52: ...ion There are some hardware configurations where it is necessary to limit the number of drives installed in the chassis For more information see Temperature requirements Prerequisites Before you perfo...

Страница 53: ...e information see the documentation that ships with the option 11 Connect all necessary internal cabling to the expansion board For more information on these cabling requirements see the documentation...

Страница 54: ...s are supported in both the primary and secondary riser slots IMPORTANT The Apollo DX2800 Gen10 Chassis with 16 NVMe drives does not support connection to the embedded Smart Array S100i SR Gen10 Softw...

Страница 55: ...evice go to the next step 5 Ensure that users are logged off and that all tasks are completed on the server CAUTION In systems that use external data storage be sure that the server is the first unit...

Страница 56: ...If installed remove the full height bracket from the controller 10 Install the low profile bracket on the controller 11 Connect the following cables to the controller 56 Hardware options installation...

Страница 57: ...If removed install the bayonet board 18 Install the air baffle on page 22 19 Install the server into the chassis on page 20 20 Connect all peripheral cables to the server 21 To enable HPE Smart Array...

Страница 58: ...procedure perform the following steps 1 Back up data on the system 2 Close all applications 3 Update the server firmware if it is not the latest revision 4 Do one of the following If the new Smart Arr...

Страница 59: ...8 If installed remove the full height bracket from the controller 9 Install the low profile bracket on the controller Hardware options installation 59...

Страница 60: ...d is firmly seated in the slot 12 If you have installed a Smart Array P class Gen10 controller connect the storage controller backup power cable to the riser board 13 Install the secondary riser cage...

Страница 61: ...er 5 Optional If running the server in Legacy Boot Mode change the controller boot order 6 If the new controller is not the new boot device install the device drivers 7 If the controller firmware is n...

Страница 62: ...he server 3 Remove the server from the chassis on page 19 4 Remove the air baffle on page 21 5 Remove the DIMM guard a Remove the DIMM guard screw b Carefully disengage the latch from the DIMM guard p...

Страница 63: ...s on page 20 10 Connect all peripheral cables to the server 11 Power up the server on page 19 The installation is complete To configure the M 2 SATA SSDs see the HPE Smart Array SR Gen10 Configuration...

Страница 64: ...rements Installing the FlexibleLOM adapter Prerequisites Before installing this option make sure that you have a T 10 and a T 15 Torx screwdrivers available Procedure 1 Power down the server on page 1...

Страница 65: ...adapter option Prerequisites Before installing this option Verify that an Intel Xeon 61XXF processor is installed in the processor socket 1 Verify that the server has at least 32 GB memory capacity Ma...

Страница 66: ...riser cage on page 29 8 Remove the primary riser slot blank 9 Connect the IFP and sideband cables to the OPA adapter 10 Install the OPA adapter in the primary riser slot Make sure that the board is fi...

Страница 67: ...the system board 14 Do one of the following Install the secondary riser blank on page 26 Install the secondary riser cage on page 28 15 If removed install the bayonet board 16 Install the air baffle o...

Страница 68: ...more information see Temperature requirements Prerequisites Before you perform this procedure make sure that you have a T 15 Torx screwdriver available Procedure 1 Power down the server on page 19 2 D...

Страница 69: ...9 Install the Media Module adapter Make sure that the board is firmly seated in the slot 10 Install the Media Module screws Hardware options installation 69...

Страница 70: ...Connect the LAN segment cables to the adapter 17 Connect all peripheral cables to the server 18 Power up the server on page 19 The installation is complete HPE Trusted Platform Module 2 0 Gen10 option...

Страница 71: ...ur operation usage of TPM which violates the above mentioned requirement you shall bear all the liabilities wholly and solely Hewlett Packard Enterprise will not be responsible for any related liabili...

Страница 72: ...the latest ROM version from the Hewlett Packard Enterprise Support Center website Follow the instructions on the website to update the system ROM 3 Power down the server on page 19 4 If an expansion b...

Страница 73: ...ly press straight down on the middle of the cover 4 Proceed to Preparing the server for operation on page 73 Preparing the server for operation Procedure 1 If an expansion board in the primary riser s...

Страница 74: ...lowing Current TPM Type is set to TPM 2 0 Current TPM State is set to Present and Enabled TPM Visibility is set to Visible 4 If changes were made in the previous step press the F10 key to save your se...

Страница 75: ...g becomes effective 8 Enable TPM functionality in the OS such as Microsoft Windows BitLocker or measured boot For more information see the Microsoft website Retaining the recovery key password The rec...

Страница 76: ...ce to verify the length of the cable Use the internal cable management features to properly route and secure the cables When routing cables be sure that the cables are not in a position where they can...

Страница 77: ...r being used Retaining them inside the server can restrict airflow If you intend to use the removed cables later label and store them for future use Smart Array cabling Onboard S100i SR Gen10 controll...

Страница 78: ...Smart Array type p controller cabling SAS SATA Smart Array type p controller cabling in the primary riser slot Smart Array type p controller cabling in the secondary riser slot 78 Cabling...

Страница 79: ...p power cabling Storage controller backup power cabling in the primary riser slot Storage controller backup power cabling in the P1 secondary riser Storage controller backup power cabling in the P2 se...

Страница 80: ...Secondary riser cabling OPA adapter cabling Cable color Description Blue OPA adapter sideband cable Orange OPA adapter IFP cable 80 Cabling...

Страница 81: ...e Administrator on page 91 Offline StorCLI on page 91 Offline All Nutanix product documentation To get a DX appliance up and running follow the instructions in the Getting Started Guide from the Nutan...

Страница 82: ...lth System does not parse or change OS data from third party error event log activities for example content created or passed through the OS Active Health System Log The data collected by the Active H...

Страница 83: ...all data for the selected iLO Federation group is retrieved iLO supports the following features Group health status View server health and model information Group virtual media Connect URL based media...

Страница 84: ...figuration inventory and monitoring tasks by sending basic HTTPS operations GET PUT POST DELETE and PATCH to the iLO web server To learn more about the iLO RESTful API see the Hewlett Packard Enterpri...

Страница 85: ...system NOTE The use of the term server represents nodes server trays server nodes and cartridges For a full description of APM features and support see the QuickSpecs on the Hewlett Packard Enterprise...

Страница 86: ...ares the system for installing original licensed vendor media and Hewlett Packard Enterprise branded versions of OS software Intelligent Provisioning also prepares the system to integrate optimized se...

Страница 87: ...Gen10 servers are built with some of the industry s most advanced security capabilities out of the box with a foundation of secure embedded management applications and firmware The management securit...

Страница 88: ...laborate to enhance platform security UEFI Graphical User Interface GUI An Embedded UEFI Shell that provides a preboot environment for running scripts and tools Boot support for option cards that only...

Страница 89: ...e Boot and have an EFI boot loader signed with one of the authorized keys to boot For more information about supported operating systems see http www hpe com servers ossupport You can customize the ce...

Страница 90: ...he initial provisioning of the server or compute module an array is required to be configured before the operating system can be installed You can configure the array using SSA HPE SSA is accessible b...

Страница 91: ...e Pack for ProLiant or SPP which you can download from http www hpe com servers spp download Be sure to use the latest SPP version for the server For more information about the MR Storage Administrato...

Страница 92: ...the new ROM becomes corrupted for any reason This feature protects the existing ROM version even if you experience a power failure while flashing the ROM Keeping the system current Updating firmware o...

Страница 93: ...ols Integrated Smart Update Tools iSUT is a software utility used with iLO 4 iLO 5 iLO Amplifier Pack HPE OneView Service Pack for ProLiant SPP and Smart Update Manager SUM to stage install and activa...

Страница 94: ...n in use 6 Select Select Firmware File 7 Select the flash file in the File Explorer list The firmware file is loaded and the Firmware Updates screen lists details of the file in the Selected firmware...

Страница 95: ...en search for the product name number Software and firmware Update software and firmware before using the server for the first time unless any installed software or components require an older version...

Страница 96: ...nd networking technology For more information see the Hewlett Packard Enterprise website http www hpe com services consulting Proactive notifications 30 to 60 days in advance Hewlett Packard Enterpris...

Страница 97: ...he iLO Virtual NMI feature Troubleshooting resources Troubleshooting resources are available for HPE Gen10 server products in the following documents Troubleshooting Guide for HPE ProLiant Gen10 serve...

Страница 98: ...atically displays the correct date and time then replace the battery that provides power to the real time clock Under normal use battery life is 5 to 10 years Removing and replacing the system battery...

Страница 99: ...server into the chassis on page 20 12 Connect all peripheral cables to the server 13 Power up the server on page 19 14 Properly dispose of the old battery For more information about proper battery dis...

Страница 100: ...tion report for this product can be found at www hpe com info reach For Hewlett Packard Enterprise product environmental and safety information and compliance data including RoHS and REACH see www hpe...

Страница 101: ...material content declaration Warranty information To view the warranty information for your product see the links provided below HPE ProLiant and IA 32 Servers and Options www hpe com support ProLiant...

Страница 102: ...41 F to 50 F and 35 C to 40 C 95 F to 104 F at sea level with an altitude derating of 1 0 C per every 175 m 1 8 F per every 574 ft above 900 m 2953 ft to a maximum of 3050 m 10 000 ft 40 C to 45 C 104...

Страница 103: ...ed on page 103 Thermal limitations for components in systems with the Enhanced Processor Performance feature disabled on page 116 The following drive options have drive capacities greater than or equa...

Страница 104: ...and nonredundant 0 to 6 drives 30 C 86 F Apollo DX2800 Gen10 Chassis 24 SFF backplane with SAS expander Redundant and nonredundant 0 to 24 drives 30 C 86 F Apollo DX2800 Gen10 Chassis 16 NVMe backplan...

Страница 105: ...acity must be greater than or equal to 10 TB 3 If the component is installed in server 1 or server 2 and the server is installed in the Apollo DX2200 Gen10 Chassis drive blanks must be installed in dr...

Страница 106: ...Chassis 24 SFF backplane with SAS expander Redundant 0 to 24 drives 35 C 95 F Apollo DX2800 Gen10 Chassis 16 NVMe backplane Redundant 0 to 4 drives 35 C 95 F 64 GB LRDIMM Apollo DX2200 Gen10 Chassis 1...

Страница 107: ...assis 12 LFF backplane Redundant and nonredundant 3 drives1 Not supported 3 drives2 Not supported 0 to 2 drives3 Not supported Apollo DX2600 Gen10 Chassis 24 SFF or 16 SFF 8 NVMe backplane Redundant a...

Страница 108: ...dundant 3 drives2 Not supported 3 drives3 Not supported 0 to 2 drives4 28 C 82 4 F Apollo DX2600 Gen10 Chassis 24 SFF or 16 SFF 8 NVMe backplane Redundant and nonredundant 0 to 6 drives 22 C 71 6 F Ap...

Страница 109: ...or 16 SFF 8 NVMe backplane Redundant and nonredundant 0 to 6 drives 30 C 86 F Apollo DX2800 Gen10 Chassis 24 SFF backplane with SAS expander Redundant and nonredundant 0 to 24 drives 30 C 86 F Apollo...

Страница 110: ...ive bays 1 2 and 2 2 Similarly if the component is installed in server 3 or server 4 and the server is installed in the Apollo DX2200 Gen10 Chassis drive blanks must be installed in drive bays 3 2 and...

Страница 111: ...22 C 71 F Copper cable 35 C 95 F Apollo DX2600 Gen10 Chassis 24 SFF or 16 SFF 8 NVMe backplane Redundant and nonredundant 0 to 6 drives Optical cable Not supported Copper cable 30 C 86 F Apollo DX280...

Страница 112: ...s InfiniBand adapters with QDR or FDR speed Apollo DX2200 Gen10 Chassis 12 LFF backplane Redundant and nonredundant 3 drives1 Optical cable Not supported Copper cable 28 C 82 4 F 3 drives2 Not support...

Страница 113: ...o DX2800 Gen10 Chassis 24 SFF backplane with SAS expander Redundant and nonredundant 0 to 24 drives Optical cable Not supported Copper cable 28 C 82 4 F Apollo DX2800 Gen10 Chassis 16 NVMe backplane R...

Страница 114: ...16 NVMe backplane Redundant and nonredundant 0 to 4 drives Optical cable Not supported Copper cable 30 C 86 F 1 The drive capacity must be less than 10 TB 2 The drive capacity must be greater than or...

Страница 115: ...Apollo DX2600 Gen10 Chassis 24 SFF or 16 SFF 8 NVMe backplane Redundant and nonredundant 0 to 6 drives 30 C 86 F Apollo DX2800 Gen10 Chassis 24 SFF backplane with SAS expander Redundant and nonredund...

Страница 116: ...let ambient temperature Processor with a TDP of 125 W or more except G6244 Apollo DX2200 Gen10 Chassis 12 LFF backplane Redundant and nonredundant 3 drives1 30 C 86 F 3 drives2 25 C 77 F 0 to 2 drives...

Страница 117: ...r than or equal to 10 TB 3 If the component is installed in server 1 or server 2 and the server is installed in the Apollo DX2200 Gen10 Chassis drive blanks must be installed in drive bays 1 2 and 2 2...

Страница 118: ...Apollo DX2800 Gen10 Chassis 24 SFF backplane with SAS expander Redundant 0 to 24 drives 35 C 95 F Apollo DX2800 Gen10 Chassis 16 NVMe backplane Redundant 0 to 4 drives 35 C 95 F 64 GB LRDIMM Apollo D...

Страница 119: ...95 F 128 GB LRDIMM Apollo DX2200 Gen10 Chassis 12 LFF backplane Redundant 3 drives1 Not supported 3 drives2 Not supported 0 to 2 drives3 30 C 86 F Apollo DX2600 Gen10 Chassis 24 SFF or 16 SFF 8 NVMe...

Страница 120: ...Maximum inlet ambient temperature P408i p controller1 Apollo DX2200 Gen10 Chassis 12 LFF backplane Redundant and nonredundant 3 drives2 22 C 71 6 F 3 drives3 Not supported 0 to 2 drives4 30 C 86 F Ap...

Страница 121: ...ith SAS expander Redundant and nonredundant 0 to 24 drives 30 C 86 F Apollo DX2800 Gen10 Chassis 16 NVMe backplane Redundant and nonredundant 0 to 4 drives 30 C 86 F E208i p controller Apollo DX2200 G...

Страница 122: ...s 35 C 95 F E208e p controller Apollo DX2200 Gen10 Chassis 12 LFF backplane Redundant and nonredundant 3 drives2 30 C 86 F 3 drives3 28 C 82 4 F 0 to 2 drives4 35 C 95 F Apollo DX2600 Gen10 Chassis 24...

Страница 123: ...installed in drive bays 3 2 and 4 2 Fibre Channel and Converged Network adapters Description Chassis Fan configuration Number of drives supported by the server Maximum inlet ambient temperature FC HB...

Страница 124: ...dundant 0 to 24 drives Optical cable 25 C 77 F Copper cable 35 C 95 F Apollo DX2800 Gen10 Chassis 16 NVMe backplane Redundant and nonredundant 0 to 4 drives Optical cable 25 C 77 F Copper cable 35 C 9...

Страница 125: ...ptical cable Not supported Copper cable 25 C 77 F 0 to 2 drives3 Optical cable 28 C 82 4 F Copper cable 35 C 95 F Apollo DX2600 Gen10 Chassis 24 SFF or 16 SFF 8 NVMe backplane Redundant and nonredunda...

Страница 126: ...ble 35 C 95 F Apollo DX2800 Gen10 Chassis 24 SFF backplane with SAS expander Redundant and nonredundant 0 to 24 drives Optical cable 22 C 71 6 F Copper cable 35 C 95 F Apollo DX2800 Gen10 Chassis 16 N...

Страница 127: ...5 C 95 F Apollo DX2800 Gen10 Chassis 16 NVMe backplane Redundant and nonredundant 0 to 4 drives Optical cable 25 C 77 F Copper cable 35 C 95 F 1 The drive capacity must be less than 10 TB 2 The drive...

Страница 128: ...SFF backplane with SAS expander Redundant and nonredundant 0 to 24 drives 35 C 95 F Apollo DX2800 Gen10 Chassis 16 NVMe backplane Redundant and nonredundant 0 to 4 drives 35 C 95 F Media Module 10Gb...

Страница 129: ...o 4 drives 30 C 86 F 1 The drive capacity must be less than 10 TB 2 The drive capacity must be greater than or equal to 10 TB 3 If the component is installed in server 1 or server 2 and the server is...

Страница 130: ...ility matrix www hpe com storage spock Storage white papers and analyst reports www hpe com storage whitepapers For additional general support websites see Support and other resources Product websites...

Страница 131: ...components Accessing updates Some software products provide a mechanism for accessing software updates through the product interface Review your product documentation to identify the recommended softw...

Страница 132: ...ise strongly recommends that you register your device for remote support If your product includes additional remote support details use search to locate that information Remote support and Proactive C...

Отзывы: