5.
Connect all peripheral cables to the server.
on page 19.
Remove the primary riser cage
CAUTION:
To prevent improper cooling and thermal damage, do not operate the server unless
either riser blank or riser cage is installed.
Prerequisites
Before you perform this procedure, make sure that you have a T-10 Torx screwdriver available.
Procedure
on page 19.
2.
Disconnect all peripheral cables from the server.
3. Remove the server from the chassis
on page 19.
on page 21.
5.
If a secondary riser option is installed,
6.
Do one of the following:
•
Remove the secondary riser blank
•
Remove the secondary riser cage
on page 27.
7.
If an expansion board with internal cabling is installed on the riser cage, disconnect these internal
cables from the expansion board.
8.
Disconnect all cables from the riser board.
9.
Remove the primary riser cage.
Operations
29