Troubleshooting
4-3
Error Recovery Procedures
Table 4-1 lists ERPs for errors reported on the front panel of the Library.
Table 4-1
Error Recovery Procedures
ERP Code
Procedure/Description
C
Cycle power to the Library using the AC switch on the front panel. Wait 30
seconds to power on again.
D
Turn off power to the Library and inspect connectors and cables.
F
Invalid operation. Select parameters correctly and try again.
Fault Symptom Codes (FSCs)
FSCs that appear on the Fault screen are described in Chapter 2, “Operation.” A descriptive
message and instructions for clearing the fault accompany each FSC. If a fault persists, look up
the FSC in Table 4-2 to determine the error recovery procedure.
Table 4-2
Fault Symptom Codes
FSC
Message
ERP
3001
Picker Tries Escd
Power Down to Clear
C,D
3002
Picker Tach Errors
Power Down to Clear
D
3003
Elevator Tach Errors
Power Down to Clear
D
3004
Elevator Jammed
Power Down to Clear
C,D
3005
Picker Jammed
Power Down to Clear
C,D
5002
All Drives/Slots Empty
Press Enter to Clear
F
5003
All Drives/Slots Full
Press Enter to Clear
F
continued