E100009B
Message
Failed to get LU object for created LU:[ LU number of secondary VOL].
Explanation
Cannot get LU# information of the secondary VOL(S-VOL/V-VOL).
Recommended action
•
(1) Confirm that the secondary VOL exists in the disk array system using Storage
Management Software.
•
(2) Overloaded process may be performed on the disk array system. Confirm the status of
the disk array system and retry after some time.
•
(3) An error occurred when an operation command was given to the disk array system.
See
“About errors attributable to disk array systems” (page 133)
E100009F
Message
Failed to get LU object for LU:[ LU number of secondary VOL].
Explanation
Cannot get LU# information of the secondary VOL(S-VOL/V-VOL).
Recommended action
•
(1) Confirm that the primary VOL exists in the disk array system using Storage Management
Software.
•
(2) An error occurred when an operation command was given to the disk array system.
See
“About errors attributable to disk array systems” (page 133)
E10000C7
Message
getPairStatus failed - P-Vol: [LU number of P-VOL].
Explanation
Cannot get a pair status/.
Recommended action
An error occurred when an operation command was given to the disk array system.
See
“About errors attributable to disk array systems” (page 133)
E10000C9
Message
P-Vol[LU number of P-VOL] pair status[Pair status] is not valid
Explanation
The pair status is invalid.
88
Troubleshooting
Содержание XP