Explanation
VSS service stopped.
Recommended action
•
(1) Confirm that the IP address of the specified disk array system is set in the setup file of
the application server.
•
(2) When using the VMware Guest to Guest Backup (FC) function, confirm that vCenter
Server is registered, and register it if not (see Subsection 7.1.2.).
•
(3) If the virtual DKC which straddles multiple physical DKCs is used, make sure that the
virtual LDEV ID of P-VOL is not duplicated in the virtual DKC. If the virtual LDEV ID of P-VOL
is duplicated, assign the virtual LDEV ID of P-VOL to prevent duplication.
•
(4)Reference the VSS Provider log files, when another Error message is output, and execute
the corresponding solutions.
•
(5) An error occurred when an operation command was given to the disk array system.
See
“About errors attributable to disk array systems” (page 133)
E200205F
Message
ResyncLuns failed for Storage Identifier 'serial number', SourceLun[LU# of S-VOL]
-->TargetLuns[LU# of P-VOL], with [Error code]
Explanation
Resynchronization failed when restoring.
Recommended action
[XP P9500/XP7]
•
(1) Using Storage Management Software, confirm and perform the following operation:
1) When a pair status for restore is not PSUS, restore operation cannot be performed.
Using Storage Management Software, make the pair status PSUS.
◦
◦
2) When restoring a cascade pair, if a pair status of other pairs except the pair to be
restored is not PSUS, a restore operation cannot be performed. Make a pair status
other than a pair for restore PSUS.
◦
3) Restore operation cannot be performed when the following reasons are applied due
to the disk array system specification.
–
Primary volume of the Business Copy pair is the virtual VOL of the Thin Provisioning
and the secondary volume of the Business Copy pair is the normal volume.
–
Primary volume of the Business Copy pair is the normal volume and the secondary
volume of the Business Copy pair is the virtual VOL of the Thin Provisioning.
[XP7]
In the case of the HA configuration, if the HA pair status to be restored is not PSUS, restore
operation cannot be performed. Change the HA pair status to PSPU using the storage
management software.
•
(2) An error occurred when an operation command was given to the disk array system.
See
“About errors attributable to disk array systems” (page 133)
Error messages
121