Recommended action
•
(1) Confirm the serial number of the disk array system using Storage Management Software
and type a proper serial number, user name, and password in the Add Storage dialog boxes
for registration of disk array systems.
•
(2) Confirm that the instance of RAID Manager specified by the hiRaidcomX configuration
file is started.
•
(3) In the case of the Ext Stor configuration or HA configuration, do not describe
HORCM_VCMD in the HORCM CONF configuration file.
E2002005
Message
Storage discovery failed. Verify IP addresses.
Explanation
Cannot acquire the information of the disk array system corresponding to the specified IP address.
Recommended action
•
(1) Perform the following using Storage Management Software:
1) Confirm the IP address of the disk array system, and type the correct IP address into
the Add Storage dialog box.
◦
◦
2) Confirm the valid/invalid setting of the Password Protection function of the specified
disk array system. If it is valid, change it to invalid.
•
(2) Confirm that the LAN cables are connected properly.
E2002006
Message
Storage user ID is not registered.
Explanation
The specified user name is not registered in the disk array system.
Recommended action
Using Storage Management Software, confirm the user name of the disk array system and type
the user name registered into the disk array system in the Add Storage dialog box.
E2002008
Message
The specified password does not match.
Explanation
The password that you input is not correct.
Recommended action
Type the correct password into the Add Storage dialog box.
Error messages
103
Содержание XP
Страница 51: ...5 Missing number 51 ...