Recommended action
•
(1)When the status of the specified pair is Split Pending, wait for the pair status to become
PSUS, or re-execute after setting a pair status to PAIR using Storage Management Software.
•
(2) An error occurred by the operation command for the disk array system.
See
“About errors attributable to disk array systems” (page 133)
E10000DE
Message
Failed to resync Business Copy pair - P-Vol:[ LU number of P-VOL] S-Vol:[ LU number of S-VOL]
Failed to resync Business Copy pair - P-Vol:[ LU number of P-VOL] V-Vol:[ LU number of V-VOL]
Explanation
Resync processing failed.
Recommended action
An error occurred when an operation command was given to the disk array system.
See
“About errors attributable to disk array systems” (page 133)
E10000DF
Message
Failed to restore Business Copy pair - P-Vol:[ LU number of P-VOL] S-Vol:[ LU number of S-VOL]
Failed to restore Business Copy pair - P-Vol:[ LU number of P-VOL] V-Vol:[ LU number of V-VOL]
Explanation
Failed to restore from Secondary VOL(S-VOL/V-VOL) to P-VOL.
Recommended action
•
(1) Perform the following using Storage Management Software:
[XP P9500/XP7]
◦
1)Confirm that the user account and password that you input are correct.
◦
2) Confirm that Storage Administrator (View and Modify) authority is assigned to a user
account, and assign it if not.
◦
3) When performing a restore operating using a cascade pair, the restore operation
cannot be performed directly from a L2 pair. Set the pair status of L1 to SMPL.
◦
4) Confirm that the volume which having operated restore is Business Copy pair or
Snapshot pair configuration.
◦
5) When operating restore with cascade connection, if a pair status other than a pair
for restore is not PSUS, the restore cannot be performed. Make a pair status other than
a PAIR for restore PSUS.
[XP7]
In the case of the HA configuration, if the HA pair status to be restored is not PSUS, restore
operation cannot be performed. Change the HA pair status to PSPU using the storage
management software.
•
(2) An error occurred when an operation command was given to the disk array system.
See
“About errors attributable to disk array systems” (page 133)