2.
Click
Next
.
3.
Choose the location for the software or use the default location (
C:\Program
Files\HP\VSSProvider\
).
When you want to change an installation destination:
a.
Click
Browse
.
b.
Select an installation folder.
When the installation folder is changed, a file is expanded under the new folder.
Only a local drive is supported as the installation drive.
Note that installation on a network drive or a removable disk is not supported. For the path
length of the installation folder, see
“Restrictions and points of consideration related to the
environmental configuration” (page 26)
.
4.
Click
Next
to start the installation. You will receive a message letting you know when the
VSS Provider is installed.
5.
Click
Finish
to complete installation.
6.
1.
Edit the configuration file in the installation folder. For the configuration file, see .
The log output level
[DebugLevel=NORMAL]
and the restore mode
[RestoreMode=NORMAL]
are described in the configuration file by default.
As the restore mode is set in
NORMAL
by default, change the mode as needed. For the
Restore
mode, see .
2.
When using a disk array system of the XP P9500/XP7, copy the HORCM_CONF
configuration file (by default, horcm700.conf) stored in the installation folder to the
installation folder of RAID Manager (by default, <system drive>:\HORCM\etc folder).
For information about the HORCM_CONF configuration file, see . User edit files
User edit files
Setup and configuration files are created in the specified installation folder during the VSS Provider
installation. If a file already exists, the file remains and is not overwritten.
Users must edit each file as needed. See
“Restrictions and points of consideration related to the
environmental configuration” (page 26)
for the items to be edited in each file.
•
Setup file (
hivss.config
)
Sets the behavior of VSS Provider. This includes items such as the Log output level of VSS
Provider and default backup mode.
•
Maintenance c file (
hilogger.config
)
Sets the behavior of the log output function. This includes items such as log file size and
the number of log generations. See for the log generation management specifications.
•
hiRaidcomX configuration file (
hiRaidcomX.config
)
Sets the instance number necessary to operate RAID Manager and the installation folder
for RAID Manager. This configuration file is only necessary for XP P9500/XP7 disk array
systems.
•
HORCM CONF configuration file (
horcm*.conf
, * = the instance number)
Sets the system configuration to operate RAID Manager. This configuration file is necessary
for XP P9500/XP7 disk array systems. The instance number listed in
hiRaidcomX.config
is indicated by an asterisk (*). The file name made when installing VSS Provider is
horcm700.conf
. In this document, "*" is assumed to be 700 and the file name is assumed
to be
horcm700.conf
.
User edit files
37