Explanation
Could not use the specified P-VOL for making Business Copy.
Recommended action
•
(1) You may have specified a P-VOL which is not targeted for a backup. Specify the correct
P-VOL.
•
(2)The specified P-VOL may not be mapped to the VSS installation server (application
server). Map it using Storage Management Software.
•
(3) Using Storage Management Software, confirm the valid/invalid setting of the Business
Copy function. If it is invalid, change it to valid.
•
(4) An error occurred when an operation command was given to the disk array system.
See
“About errors attributable to disk array systems” (page 133)
E2002019
Message
S-Vol cannot be created for this volume. P-Vol is being formatted.
Explanation
Creation of S-VOL failed. P-VOL is being formatted.
Recommended action
Create the S-VOL after P-VOL formatting is complete.
E200201A
Message
Creation of S-Vol failed: The LU is already paired.
Explanation
Creation of S-VOL failed. The pair status of the LU is already PAIR
Recommended action
The pair status of the specified LU is already PAIR. Specify the correct LU and re-execute.
E200201B
Message
Operation Failed. message
Explanation
Operation Failed.
Recommended action
[XP P9500/XP7]
•
(1) If Host group: HP-VSS-HG does not exist, create HP-VSS-HG.
•
(2) Check that it does not come into conflict with the operational restrictions and points of
consideration when using RAID Manager. See Table 2.5.2-3.
•
(3) See the log file and provide solutions for any error messages were output.
Error messages
107