Explanation
Could not remove S-VOL/V-VOL from the target.
Recommended action
•
(1) Using Storage Management Software, unmaps S-VOL/V-VOL from the target of the
target name in the message column. In addition, delete V-VOL at the time of the backup in
Snapshot.
•
(2) An error occurred when an operation command was given to the disk array system.
See
“About errors attributable to disk array systems” (page 133)
E1000126
Message
Invalid Controller IP in configuration file.
Explanation
The format of an IP address in the setup file is incorrect.
Recommended action
•
(1) Confirm the IP address of the disk array system using Storage Management Software,
and set the IP address of the disk array system in the proper format in the setup file (See
Subsection 3.2.1).
•
(2) Confirm that only single-byte alphanumeric characters were used in the setup file.
E1000138
Message
Failed to connect to device. Serial number: [serial number], Error: [Error code].
Explanation
Could not connect to the disk array system corresponding to the registered serial number.
Recommended action
•
(1) Confirm whether HORCM starts.
•
(2) Confirm that the FC cables are connected properly.
•
(3) Confirm that the contents of hiRaidcomX.config are correct.
•
(4) Confirm the serial number of the disk array system and user name using Storage
Management Software, and then type the proper serial number, user name, and password
into the Add Storage dialog box for registration of disk array systems.
E1000139
Message
Configuration file does not have any valid serial numbers or IP addresses.
Explanation
The setup file does not contain IP addresses in the correct format.
Error messages
99
Содержание XP