hiRaidcomX
configuration file item description and entry format:
•
Instance number — Instance number of RAID Manager (value of HORCMINST)
Format: Instance=<RAID Managerinstance #>
An error occurs if you specify an instance number that does not reboot or if you omit this
item.
•
Installation folder of RAID Manager (HORCM) — Install folder of RAID Manager
Format: RAID ManagerInstall=<RAID Managerinstallation folder>
An error occurs if you specify an incorrect path or if you omit this item.
Example 3
hiRaidcomX
configuration file
Instance=700
CCIInstall=C:\HORCM
When the same item is listed on multiple lines
When the instance number or the installation folder of RAID Manager is listed on multiple lines,
the final line takes precedence. In the following example, 700 becomes the instance number.
Example:
Instance=600
Instance=700
HORCM CONF
configuration file item description and entry format:
•
HORCM_CMD — Physical drive number of the command device
Specify the physical drive number with the value in <num>.
For details about the
HORCM CONF
configuration file and conformation method of physical
drive number, see RAID Manager User Guide chapter 2. Configuration Definition Files.
Format: \\.\PHYSICALDRIVE<num>
Example 4
HORCM CONF
configuration file
#dev_namedev_name
\\.\PHYSICALDRIVE21
When using VMware Guest to Guest Backup (FC) function
In case of backing up XP P9500/XP7 from the multiple virtual machines on the same ESXi at
the same time, specify different RAID Manager instance number for each virtual machine.
NOTE:
This restriction is not applied when virtual machines are on different ESXi.
If instance numbers are duplicated, IO conflict occurs between instances depending on the timing
of process request to the disk array system, which may lead to the backup failure.
For the details, see “Restrictions for VMware ESX Server” in RAID Manager installation and
Configuration Guide.
44
Configuration Procedure
Содержание XP