Table 8 Storages window properties
Remarks
Description
Property name
Storage registration index
Index
In the case of the virtual DKC, storage
device type of virtual DKC is displayed.
Disk array system type
Type
In the case of the virtual DKC, storage
device serial number of virtual DKC is
displayed.
Storage serial number
Serial Number
In the case of the virtual DKC,
command device of physical DKC is
displayed.
Command device
Command Device
Add Storage
A disk array system is registered for use by VSS Provider.
To register a disk array system:
1.
Click
Add Storage
in the VSS Hardware Provider configuration window.
The
Add Storage
dialog box is displayed
2.
Input the following information depending on the type of the disk array system.
a.
Select XP P9500 or XP7 in
Storage Model
pull down menu.
b.
Enter the Serial Number of the disk array system to be added. (Input is limited to up to
6 single-byte alphanumeric characters.)
NOTE:
•
In the case of XP7, enter the six digits which has the disk array system serial number
identifier "3" to the head of zero padded five digits serial number.
<Example> If the serial number is “2”, enter as “300002”.
•
In the case of virtual DKC, enter the serial number of virtual DKC.
3.
Enter the User Name and Password. (Input is limited to up to 255 single-byte alphanumeric
characters.).
4.
Click
OK
.
The
Loading added storage information ... please wait
message is displayed
on
Storages
window until the connection to a disk array system is completed.
Click
Cancel
in the
Add Storage
dialog box if you decide not to add the disk array system.
When the connection to the disk array system completes, the disk array system specified
in
Add Storage
dialog box is displayed in the
Storages
window.
NOTE:
•
The XP P9500/XP7 require time for gathering information and will wait in the same status
for a while.
•
It is not necessary to enter the serial number of the disk array system again the next time
because the registration information of the disk array system is maintained in the setup file.
To remove a disk array system from VSS Provider, manually delete the serial number from the
configuration file and save the file. When you close the GUI tool and start it again, the disk array
system is removed from the
Storages
window. See
for details about the
setup file.
Functions of GUI tool
55
Содержание XP