Hardware options installation 30
Hardware options installation
Introduction
If more than one option is being installed, read the installation instructions for all the hardware options and
identify similar steps to streamline the installation process.
WARNING:
To reduce the risk of personal injury from hot surfaces, allow the drives and the
internal system components to cool before touching them.
CAUTION:
To prevent damage to electrical components, properly ground the server before
beginning any installation procedure. Improper grounding can cause electrostatic discharge.
HP product QuickSpecs
For more information about product features, specifications, options, configurations, and compatibility, see
the product QuickSpecs on the HP Product Bulletin website (
http://www.hp.com/go/productbulletin
).
SAS and SATA drive options
The server provides non-hot-plug capability through an embedded SATA controller. To obtain hot-plug
capability, install an optional controller and hot-plug cable option kit. The server supports up to four
non-hot-plug or hot-plug LFF drives and up to eight hot-plug SFF drives.
Drive installation guidelines
When adding drives to the server, observe the following general guidelines:
•
The system automatically sets all drive numbers.
•
If only one drive is used, install it in the bay with the lowest drive number.
•
When drives are grouped together into the same drive array, they must be of the same capacity to
provide the greatest storage space efficiency.
Optional storage controllers provide support for hot-plug capability and drive LEDs. Controller options are:
•
The embedded controller supports non-hot-plug SATA drives. Drive LEDs are not supported.
•
Optional SATA controllers support hot-plug SATA drives and drive LEDs.
•
Optional SAS controllers support hot-plug SAS or SATA drives and drive LEDs.
Installing a drive
CAUTION:
To prevent improper cooling and thermal damage, do not operate the server unless
all bays are populated with either a component or a blank.
Содержание ProLiant ML110 G7
Страница 6: ...Contents 6 ...
Страница 13: ...Component identification 13 SAS and SATA drive numbering Four bay LFF drive model Eight bay SFF drive model ...
Страница 86: ...Troubleshooting 86 ...
Страница 105: ...Support and other resources 105 ...
Страница 106: ...Support and other resources 106 ...