HP ProLiant server errors 94
1833-Slot X Drive Array – Unsupported Array Configuration Detected
...One or more logical drive(s) are configured for RAID fault tolerance level(s) that are not supported.
Action:
For supported configurations, see the user guide.
Event list error messages
Introduction to event list error messages
This section contains event list error messages recorded in the IML, which can be viewed through different
tools.
The format of the list is different when viewed through different tools. An example of the format of an event
as displayed on the IMD follows:
**001 of 010**
---caution---
03/19/2002
12:54 PM
FAN INSERTED
Main System
Location:
System Board
Fan ID: 03
**END OF EVENT**
WARNING:
To avoid potential problems, ALWAYS read the warnings and cautionary
information in the server documentation before removing, replacing, reseating, or modifying
system components.
IMPORTANT:
This guide provides information for multiple servers. Some information may not
apply to the server you are troubleshooting. Refer to the server documentation for information on
procedures, hardware options, software tools, and operating systems supported by the server.
NOTE:
The error messages in this section may be worded slightly different than as displayed by
the server.
A CPU Power Module (System Board, Socket X)...
...A CPU Power Module (Slot X, Socket Y) Failed
Event Type
: Power module failure
Action
: Replace the power module. In the case of an embedded power module, replace the system board.
ASR Lockup Detected: Cause
Event Type
: System lockup
Action
: Examine the IML to determine the cause of the lockup. For more information, refer to the
HP
ROM-Based Setup Utility User Guide
on the server Documentation CD or the SmartStart Support and
Documents website (
http://www.hp.com/support/smartstart/documentation
).