HP ProLiant server errors 90
1797-Slot X Drive Array - Write-Back Cache Read Error Occurred...
...Data in Cache has been lost. Caching is disabled.
Audible Beeps
: None
Possible Cause
: Hard parity error detected while reading data from posted-writes memory.
Action
: Replace the cache module.
1798-Slot X Drive Array - Cache Module Self-Test Error Occurred...
...Caching is disabled.
Audible Beeps
: None
Possible Cause
: Cache Module failed self-test. Depending on the array controller model, the cache may be
disabled or the controller might not be usable until this problem is corrected.
Action
: Replace the Cache Module.
1799-Slot X Drive Array - Drive(s) Disabled due to Write-Back Cache Data Loss....
...Select “F1” to continue with logical drives disabled.
Select “F2” to accept data loss and to re-enable logical drives.
Audible Beeps
: None
Possible Cause
: One or more logical drives failed due to loss of data in posted-writes memory.
Action
:
•
Press the
F1
key to continue with the logical drives disabled.
•
Press the
F2
key to accept data loss and re-enable logical drives. After pressing the
F2
key, check the
integrity of the file system and restore lost data from backup.
1800 Series
1802-Slot X Drive Array - Dual domain configured or detected but not supported by
this configuration
Audible beeps:
None
Possible cause:
A dual domain has been configured or detected, but is not supported.
Action:
Perform one of the following:
•
Remove the extra cabling and shift back to single domain.
•
Upgrade the controller/SAAP license to enable dual domain.
1803-Slot X Drive Array - Cache Module is not installed;...
IMPORTANT: Unsupported Configuration: Controller performance and supported configurations are limited.
Action: Install the Cache Module to remove these limitations.
Audible Beeps:
None
Possible Cause:
The Cache Module is not installed.
Action:
Install the Cache Module to remove the limitations.