HP ProLiant server errors 62
292- Invalid HP Software RAID Configuration
...HP B140i SW RAID Mode is NOT supported when the Boot Mode is configured for Legacy BIOS Mode.
Action:
Configure the Boot Mode to UEFI Mode if using HP SW RAID.
293- A critical error occurred resulting in a reboot of the system
...The source of the error could not be identified.
Action:
Check hardware and software for issues. If the issue persists, contact HP service.
294- Memory Board X Training Failure
...DIMMs on this Memory Board are not available to the operating system.
Action:
Reseat the Memory Board. If the issue persists, contact HP Support.
295- DIMM Failure – Uncorrectable Memory Error – Processor X, DIMM Y
...This memory will not be available to the operating system.
Action:
Replace the failed DIMM to restore the full amount of memory.
295- DIMM Failure – Uncorrectable Memory Error – Memory Board X, DIMM Y
...This memory will not be available to the operating system.
Action:
Replace the failed DIMM to restore the full amount of memory.
296- DIMM Configuration Error – Processor X, DIMM Y – Non-production DIMM
detected
...System halted.
Action
: Remove non-production DIMM.
297- IMPORTANT: The iLO Security switch is set to the ON position
...Platform security is DISABLED.
Action:
Set this switch to the OFF position for normal operation.
298- IMPORTANT: The Boot Mode has been changed to Legacy Boot Mode for this
boot only
...On the next reboot, the Boot Mode will return to UEFI Boot Mode.
Action:
No action required
299- IMPORTANT: The Boot Mode has been changed to UEFI Boot Mode for this
boot only
...On the next reboot, the Boot Mode will return to Legacy Boot Mode.
Action:
No action required