![HP ProLiant Gen9 Скачать руководство пользователя страница 383](http://html.mh-extra.com/html/hp/proliant-gen9/proliant-gen9_troubleshooting-manual_164808383.webp)
Microsoft Windows Event ID and SNMP traps 383
Supporting SNMP Trap Description: “Power subsystem has too may power enclosures
[cpqRackCommonEnclosureName], in rack [cpqRackName].”
NT Event ID: 1178 (Hex)0x8435049a (cpqsvmsg.dll)
Log Severity: Warning (2)
Event Title: Power Subsystem Configuration Error
Log Message: The power subsystem has been improperly configured.
SNMP Trap: cpqRackPowerChassisConfigError - 22036 in CPQRACK.MIB
Symptom: Power subsystem improperly configured. The power subsystem has been improperly configured.
User Action: Check the cabling of the power enclosure.
Supporting SNMP Trap Data:
•
sysName
•
cpqHoTrapFlags
•
cpqRackName
•
cpqRackUid
•
cpqRackCommonEnclosureName
•
cpqRackCommonEnclosureSerialNum
•
cpqRackCommonEnclosureSparePartNumber
•
cpqRackCommonEnclosureTrapSequenceNum
Supporting SNMP Trap Description: “Power subsystem has been improperly configured in enclosure
[cpqRackCommonEnclosureName], in rack [cpqRackName].”
NT Event ID: 1179 (Hex) 0x8435049B (cpqsvmsg.dll)
Log Severity: Warning (2)
Log Message: The Management Processor is in reset state. The data contains the error code.
SNMP Trap: cpqHeManagementProcInReset - 6061 in CPQHLTH.MIB
Symptom: The Management processor is currently in reset. The management processor is currently in the
process of being reset because of a firmware update or some other event.
User action: None
Supporting SNMP Trap Data:
•
sysName
•
cpqHoTrapFlags
Supporting SNMP Trap Description: “The Management processor is in the process of being reset.”
NT Event ID: 1180 (Hex) 0x0435049c (cpqsvmsg.dll)
Log Severity: Informational (1)
Log Message: The Management Processor has successfully reset and is now available again. The data
contains the error code.
SNMP Trap: cpqHeManagementProcReady - 6062 in CPQHLTH.MIB