HP ProLiant server errors 80
1748-Slot X Drive Array - Unsupported Cache Module Battery Attached...
...Please install Battery Pack(s) with the correct part number.
Audible Beeps
: None
Possible Cause
: The current battery pack is not supported on this cache module.
Action
: Install only supported battery packs with the correct part number.
1749-Slot X Drive Array - Cache Module Flash Memory being erased...
...Caching will be re-enabled when flash memory erase has completed.
Audible Beeps
: None
Possible Cause
: The cache module flash memory is being erased.
Action
: No action is required.
1752- Slot X Drive Array...
...Controller not supported in this server model.
Action:
Replace the Smart Array controller with a supported model.
1753-Slot X Drive Array - Array Controller Maximum Operating Temperature
Exceeded During Previous Power Up
Audible Beeps
: None
Possible Cause
: The controller is overheating.
Action
: Be sure adequate system cooling and sufficient airflow across the controller are available.
1754-Slot X Drive Array - One or more RAID levels are configured...
...but are not supported due to controller model or an inactive/missing license key. Please re-attach drives to original
controller or enter license key.
Audible Beeps
: None
Possible Cause
: The controller model does not support the configuration on the drives, or the license key is
inactive or missing.
Action
: Re-attach drives to the original controller, or enter a license key.
1762-Slot X Drive Array - Controller Firmware Upgrade Needed
...(Unsupported Cache Module Attached)
....Caching is disabled.
Audible Beeps
: None
Possible Cause
: The current controller firmware does not support the attached cache module type.
Action
: Upgrade the controller firmware, or replace the cache module.