HP ProLiant server errors 48
3.
Follow the onscreen directions:
Remove power to USB drive and reboot.
The following message should appear:
OBDR is now enabled for the attached USB tape drive.
WARNING: A Type 2 Header PCI Device Has Been Detected...
The BIOS will not configure this card.
It must be configured properly by the OS or driver.
Possible Cause
: Only Type 0 and Type 1 Header PCI devices are configured by the system ROM. The device
does not work unless the OS or device driver properly configures the card. Typically this message only occurs
when PCI cards with a PCI to PCMCIA bridge are installed.
Action
: See the operating system documentation or the device driver information that ships with the Type 2
PCI device.
WARNING - iLO 2 not responding. System health monitoring has been disabled.
Audible Beeps
: None
Possible Cause
: The iLO 2 firmware is not responding. The iLO 2 firmware may be corrupt.
Action
: If the iLO 2 firmware is corrupt, update the iLO 2 firmware using the Firmware Maintenance CD.
WARNING - iLO 3 not responding. System health monitoring has been disabled.
Audible Beeps
: None
Possible Cause
: The iLO firmware is not responding. The iLO firmware may be corrupt.
Action
: If the iLO firmware is corrupt, update the iLO firmware using the Firmware Maintenance CD or DVD,
or Smart Update Firmware DVD.
WARNING - Mixed Stepping Processors were detected. System cannot proceed.
Possible cause
: One or more 800-MHz front side bus speed processors have been initialized at 667-MHz.
Action
:
CAUTION:
Before removing or replacing any processors, be sure to follow the guidelines
provided in "Performing processor procedures in the troubleshooting process." Failure to follow
the recommended guidelines can cause damage to the system board, requiring replacement of
the system board.
Correct the processor configuration.