Hardware options installation 50
DIMM type DIMM rank
1 DIMM per channel 2 DIMMs per channel 3 DIMMs per channel
HDIMM
Dual-rank (16 GB) N/A
N/A
1333
4
1
RDIMM supports 1.35V 3DPC at 1066. Third-party memory supports 1.5V 3DPC at 1066 MT/s.
2
LRDIMM enables 3 DIMMs per channel. HP SmartMemory supports up to 3DPC at 1066 MT/s at 1.35V. Third-party
memory supports 1.5V only.
3
UDIMM is supported at 2DPC at 1333 MT/s using HP SmartMemory only. Third-party memory supports up to 2DPC at
1066 MT/s.
4
HDIMM memory requires 12 DIMMs per processor.
HP SmartMemory
HP SmartMemory, introduced for Gen8 servers, authenticates and unlocks certain features available only on
HP Qualified memory and verifies whether installed memory has passed HP qualification and test processes.
Qualified memory is performance-tuned for HP ProLiant and BladeSystem servers and provides future
enhanced support through HP Active Health and manageability software.
Certain performance features are unique with HP SmartMemory. HP SmartMemory 1.35V DDR3-1333
Registered memory is engineered to achieve the same performance level as 1.5V memory. For example,
while the industry supports DDR3-1333 RDIMM at 1.5V, this Gen8 server supports DDR3-1333 RDIMM up
to 3 DIMMs per channel at 1066 MT/s running at 1.35V. This equates to up to 20% less power at the DIMM
level with no performance penalty. In addition, the industry supports UDIMM at 2 DIMMs per channel at
1066 MT/s. HP SmartMemory supports 2 DIMMs per channel at 1333 MT/s, or 25% greater bandwidth.
Memory subsystem architecture
The memory subsystem in this server is divided into channels. Each processor supports four channels, and
each channel supports three DIMM slots, as shown in the following table.
Channel
Population order
Slot number
1
A
E
I
12
11
10
2
B
F
J
9
8
7
3
C
G
K
1
2
3
4
D
H
L
4
5
6
For the location of the slot numbers, see "DIMM slot locations (on page
18
)."
This multi-channel architecture provides enhanced performance in Advanced ECC mode. This architecture
also enables Lockstep and Online Spare Memory modes.
DIMM slots in this server are identified by number and by letter. Letters identify the population order. Slot
numbers indicate the DIMM slot ID for spare replacement.
Содержание ProLiant DL380p Gen8
Страница 6: ...Contents 6 Index 131 ...
Страница 47: ...Hardware options installation 47 14 Install the heatsink 15 Remove the two fan blanks ...
Страница 91: ...Cabling 91 Cabling SAS hard drive cabling SFF hard drive cabling SFF cabling with optional drive cage ...
Страница 92: ...Cabling 92 LFF hard drive cabling Optical drive cabling ...
Страница 93: ...Cabling 93 FBWC cabling 8 or 16 drive SFF 8 drive LFF ...
Страница 98: ...Cabling 98 Connect the cable as indicated ...
Страница 125: ...Support and other resources 125 ...
Страница 126: ...Support and other resources 126 ...