2–26
HSG80 Array Controller V8.7 Command Line Interface Reference Guide
CLI Command Descriptions
•
In asynchronous mode, OUTSTANDING_IO refers to the number of write
operations that can be reported as completed to the host before they have been
written on all the members of the remote copy set.
Example
To create remote copy set RCS1, consisting of unit D1 on the local controller pair and
unit D21 on a remote controller pair (node) named London, enter:
ADD REMOTE_COPY_SETS RCS1 D1 LONDON\D21
See Also
ADD ASSOCIATIONS
SET controller REMOTE_COPY
SET remote-copy-set-name