HSG80 Array Controller V8.7 Command Line Interface Reference Guide
2–107
SET controller
Changes specified switch values on the specified controller. “This controller”
indicates the controller that is connected to the maintenance terminal while executing
CLI commands. “Other controller” is the controller not connected to the maintenance
terminal in dual-redundant controller configurations.
NOTE: After doing a SET command to either controller, use a SHOW THIS_CONTROLLER
and a SHOW OTHER_CONTROLLER command to verify that the changes went into effect.
Syntax
SET controller
Parameter
controller
Identifies which controller is to be set. Specify THIS_CONTROLLER (the one
connected to the CLI maintenance terminal) or OTHER_CONTROLLER.
Switches
Table 2–3 lists the switches available with this command. Descriptions of the switches
follow the table.
SET
controller
Table 2–3: SET controller Switches
Switch
Values
ALLOCATION_CLASS
0-4294967295, 0 (default)
CACHE_FLUSH_TIMER=n
1-65535, 10 (default)
COMMAND_CONSOLE_LUN
NOCOMMAND_CONSOLE_LUN
None
CONNECTIONS_LOCKED
CONNECTIONS_UNLOCKED
None
INDENTIFIER=n
NOIDENTIFIER
1-9999
MIRRORED_CACHE
NOMIRRORED_CACHE
None
NODE_ID
nnn-nnnn-nnnn-nnnn xx