2–172
HSG80 Array Controller V8.7 Command Line Interface Reference Guide
CLI Command Descriptions
Example
BOT> show M1
Name Storageset Uses Used by
------------------------------------------------------------------
M1 mirrorset DISK10000 S1
DISK20000
DISK20400
Switches:
POLICY (for replacement) = BEST_PERFORMANCE
COPY (priority) = NORMAL
READ_SOURCE = LEAST_BUSY
MEMBERSHIP = 3, 3 members present
State:
RECONSTRUCTING
DISK20000 (member 0) is NORMAL
DISK20400 (member 1) is NORMAL
DISK10000 (member 2) is COPYING 6% complete
Size: 71114623 blocks
See Also
ADD MIRRORSETS
DELETE container-name
SHOW MIRRORSETS
SHOW STRIPESETS