2–160
HSG80 Array Controller V8.7 Command Line Interface Reference Guide
CLI Command Descriptions
Displays information about the specified controller.
Syntax
SHOW controller
Parameters
controller
Identifies which controller is displayed. Specify THIS_CONTROLLER (the one
connected to the CLI maintenance terminal) or OTHER_CONTROLLER.
Switches
The following switch is available for the SHOW controller command:
•
FULL
Example
To display the full information for a controller, enter:
SHOW OTHER_CONTROLLER FULL
Controller:
HSG80 (c) Compaq xxxxxxxxxx Software xxxxxx, Hardware xxxx
NODE_ID = 5000-1FE1-0005-9C10
ALLOCATION_CLASS = 1
SCSI_VERSION = SCSI-2
Configured for MULTIBUS_FAILOVER with ZG95005203
In dual-redundant configuration
Device Port SCSI address 7
Time: NOT SET
Command Console LUN is lun 0 (NOIDENTIFIER)
Host Connection Table is NOT locked
Smart Error Eject Disabled
Host PORT_1:
Reported PORT_ID = 5000-1FE1-0005-9C13
PORT_1_TOPOLOGY = FABRIC (connection down)
Host PORT_2:
Reported PORT_ID = 5000-1FE1-0005-9C14
PORT_2_TOPOLOGY = FABRIC (connection down)
NOREMOTE_COPY
SHOW
controller