2–84
HSG80 Array Controller V8.7 Command Line Interface Reference Guide
CLI Command Descriptions
This command only applies to BA370 enclosure configurations for turning O
FF
the
power to the subsystem enclosure.
NOTE: Stop all I/O operations between the hosts and controllers before issuing a POWEROFF
command.
Syntax
POWEROFF
Parameters
There are no parameters for this command.
Switches
The following switches are available for use with the POWEROFF command:
•
BATTERY and BATTERY_OFF
•
OVERRIDE_BAD_FLUSH and NO_OVERRIDE_BAD_FLUSH
•
SECONDS
These switches are described in the following paragraphs:
BATTERY _ON
BATTERY_OFF (default)
Instructs the external cache battery (ECB) charger to turn O
FF
or remain O
N
.
•
Specify BATTERY_ON to keep the ECB charger O
N
after the POWEROFF
command is issued.
•
Specify BATTERY_OFF to turn O
FF
the ECB charger after the POWEROFF
command is issued.
NOTE: The ECB LEDs will continue to F
LASH
in both cases, but the cache module LEDs cease
F
LASHING
when BATTERY_OFF is used.
OVERRIDE_BAD_FLUSH
NO_OVERRIDE_BAD_FLUSH (default)
Instructs the controller to either power O
FF
the enclosure or remain O
N
depending
on the cache flush results.
POWEROFF