HSG80 Array Controller V8.7 Command Line Interface Reference Guide
2–19
ADD PASSTHROUGH
•
target—Designates the SCSI target ID of the passthrough device on the port.
Valid device target IDs for single controller configurations are 00–15,
excluding ID 7. Valid device target IDs for dual controller configurations are
00–15, excluding IDs 6 through 7.
•
lun—Indicates the LUN of the passthrough device.
The parameters port, target, and lun must be entered with at least one space between
them. Leading zeroes can be excluded.
Switches
The following switch is available with the ADD PASSTHROUGH command:
•
TRANSFER_RATE_REQUESTED
These switches are described in the following paragraphs:
TRANSFER_RATE_REQUESTED=ASYNCHRONOUS
TRANSFER_RATE_REQUESTED=DEFAULT
TRANSFER_RATE_REQUESTED=20MHZ (default)
TRANSFER_RATE_REQUESTED=10MHZ
TRANSFER_RATE_REQUESTED=5MHZ
Specifies the maximum data transfer rate at which the controller is to
communicate with the passthrough device. The transfer rate might need to be
limited to accommodate long cables between the controllers and the device.
Examples
To add PASS10200 at port 1, target 2, LUN 0, enter:
ADD PASSTHROUGH PASS10200 1 2 0
ADD UNIT P4 PASS10200
See Also
ADD UNITS
DELETE container-name
LOCATE
SHOW DISKS
SHOW DEVICES
SHOW PASSTHROUGH
SET container-name