2–116
HSG80 Array Controller V8.7 Command Line Interface Reference Guide
CLI Command Descriptions
Examples
To change the “this controller” CLI prompt, enter:
SET THIS_CONTROLLER PROMPT=“TOP”
To change the “other controller” CLI prompt, enter:
SET OTHER_CONTROLLER PROMPT=“CONTROLLER B”
To set the name of the controller pair and put the controller pair in remote copy mode,
enter:
SET THIS_CONTROLLER REMOTE_COPY=LONDON
NOTE: The “other controller” in the pair automatically receives the same name.
SMART Error Drive Eject Disabled example:
AP_TOP> show this
Controller:
HSG80 ZG02804912 Software V87S-0, Hardware E12
NODE_ID = 5000-1FE1-FF00-0090
ALLOCATION_CLASS = 1
SCSI_VERSION = SCSI-3
Configured for MULTIBUS_FAILOVER with ZG02804288
In dual-redundant configuration
Device Port SCSI address 7
Time: 22-NOV-2001 01:14:32
Command Console LUN is lun 0 (IDENTIFIER = 99)
Host Connection Table is NOT locked
Smart Error Eject Disabled
...