HSG80 Array Controller V8.7 Command Line Interface Reference Guide
CLI Command Descriptions
Sets operating parameters for the environmental monitoring unit (EMU) in a BA370
enclosure.
In subsystems with more than one BA370 enclosure, and therefore more than one
EMU, the SET EMU command controls both the master and slave EMU settings. The
EMU within the primary (master) enclosure instructs the EMUs within the other
enclosures to operate at the same settings as the master EMU.
Syntax
SET EMU
Parameters
There are no parameters for this command.
Switches
The following switches are available to the SET EMU command:
•
ALARM
•
FANSPEED
•
SENSOR-n-SETPOINT
These switches are described in the following paragraphs:
ALARM=silent
ALARM=audible
Determines whether or not the audible alarm of the EMU will sound in the
following cases:
•
Drive failure
•
Controller restart
The EMU alarm will still sound in the event of an adverse environmental
condition, such as a power failure or an over-temperature condition.
FANSPEED=HIGH
FANSPEED=AUTOMATIC (default)
Sets the speed at which the fan operates.
SET EMU