HSG80 Array Controller V8.7 Command Line Interface Reference Guide
2–99
SET association-set-name
Changes the characteristics of an association set.
NOTE: This command works only in a DRM environment and requires an HSG80 array
controller with ACS version 8.7P code. Like all DRM commands, use of this command is heavily
restricted. Refer to the StorageWorks by Compaq Data Replication Manager HSG80 ACS
Version 8.7P Operations Guide for examples of usage.
Syntax
SET association-set-name
NOTE: Only one characteristic of an association set can be changed at any one time; therefore,
only one switch at a time can be specified with any SET association-set-name command.
Parameters
association-set-name
These name of the association set whose characteristics are to be changed.
Switches
The following switches are available for the SET association-set-name command:
•
ADD
•
FAIL_ALL and NOFAIL_ALL
•
LOG_UNIT and NOLOG_UNIT
•
ORDER_ALL and NOORDER_ALL
These switches are described in the following paragraphs:
ADD=remote-copy-set-name
This switch adds the specified remote copy set to the association set.
FAIL_ALL
NOFAIL_ALL
This switch determines the failsafe lock operation of members of the association
set. (Failsafe lock is a condition a remote copy set assumes under certain
potentially catastrophic error conditions. The failsafe locked condition prevents
further write operations from the host to the remote copy set members.)
SET
association-set-name