
3-17
Troubleshooting
Execution Error
Execution Error
An error number in the range [-299 to -200] indicates that an error has been
detected by the instrument’s execution control block. The occurrence of any error
in this class will cause the execution error bit (bit 4) in the event status register
(IEEE 488.2, section 11.5.1) to be set. If this bit is set, one of the following events
has occurred:
•
A <PROGRAM DATA> element following a header was evaluated by the device as
outside of its legal input range or is otherwise inconsistent with the device’s
capabilities.
•
A valid program message could not be properly executed due to some device condition.
Execution errors will be reported by the device after rounding and expression
evaluation operations have been completed. Rounding a numeric data element, for
example, will not be reported as an execution error. Events that generate execution
errors will not generate command errors, device-specific errors, or query errors;
see the error definitions in this chapter.
Execution Error Message Descriptions
This section lists the signal generator’s execution error messages and their
associated descriptions.
Error Number Error Description [description/explanation/examples]
-200
Execution Error
This is a generic syntax error for devices that cannot detect
more specific errors. The code indicates only that an execution
error as defined in IEEE 488.2, 11.5.1.1.5 has occurred.
-201
Invalid while in local
Indicates that a command is not executable while the device is
in local mode due to a hard local control (see IEEE 488.2,
5.6.1.5). For example, a device with a rotary switch receives a
message which would change the switch’s state, but the device
is in local so the message cannot be executed.
Содержание ESG Series
Страница 3: ...ii ...
Страница 29: ...1 12 Preparing for Use Verifying Signal Generator Operation ...
Страница 43: ...2 14 Using Functions Saving and Recalling an Instrument State ...
Страница 95: ...3 52 Troubleshooting HP Sales and Service Offices ...
Страница 109: ...4 14 Front and Rear Panel Rear Panel Overview ...
Страница 111: ...5 2 Hardkey and Softkey Reference ...
Страница 135: ...5 26 Hardkey and Softkey Reference Ampl ...
Страница 137: ...5 28 Hardkey and Softkey Reference Amplitude ...
Страница 139: ...5 30 Hardkey and Softkey Reference Arrow Keys ...
Страница 141: ...5 32 Hardkey and Softkey Reference Display Contrast Keys ...
Страница 161: ...5 52 Hardkey and Softkey Reference FM ...
Страница 169: ...5 60 Hardkey and Softkey Reference Frequency ...
Страница 171: ...5 62 Hardkey and Softkey Reference Help ...
Страница 173: ...5 64 Hardkey and Softkey Reference Hold ...
Страница 175: ...5 66 Hardkey and Softkey Reference Incr Set ...
Страница 195: ...5 86 Hardkey and Softkey Reference LF Out ...
Страница 197: ...5 88 Hardkey and Softkey Reference Local ...
Страница 199: ...5 90 Hardkey and Softkey Reference Mod On Off ...
Страница 200: ...5 91 Hardkey and Softkey Reference Mode Mode This front panel key is reserved for future use ...
Страница 201: ...5 92 Hardkey and Softkey Reference Mode ...
Страница 203: ...5 94 Hardkey and Softkey Reference Numeric Keypad ...
Страница 225: ...5 116 Hardkey and Softkey Reference Power Switch ...
Страница 235: ...5 126 Hardkey and Softkey Reference Preset ...
Страница 241: ...5 132 Hardkey and Softkey Reference Pulse ...
Страница 245: ...5 136 Hardkey and Softkey Reference Recall ...
Страница 247: ...5 138 Hardkey and Softkey Reference Return ...
Страница 249: ...5 140 Hardkey and Softkey Reference RF On Off ...
Страница 255: ...5 146 Hardkey and Softkey Reference Save ...
Страница 275: ...5 166 Hardkey and Softkey Reference Sweep List ...
Страница 311: ...6 10 Options and Accessories Upgrade and Retrofit Kits ...
Страница 312: ...7 1 7 Operation This chapter is reserved for future use ...
Страница 313: ...7 2 Operation ...
Страница 322: ...8 9 Safety and Regulatory Declaration of Conformity Declaration of Conformity ...
Страница 341: ...9 18 Specifications HP ESG Series Signal Generators Specifications ...