AM
AM Source
Pressing this softkey reveals a menu of choices for amplitude modulation sources.
You can choose internally-generated amplitude modulation or select an
externally-applied signal from either the EXT 1 INPUT or EXT 2 INPUT
connectors. The internal modulation is always AC-coupled. For the
externally-applied signals, you can choose between AC- and DC-coupled
modulation. A 1.0 Vpk input is required for calibrated AM depth settings. The
EXT 1 LO/HI
and
EXT 2 LO/HI
display annunciators will turn on if the peak
input voltage differs from 1.0 Vpk by more than 3%. (The LO/HI annunciators
only function for AC-coupled external inputs.)
The internal and external 1 and 2 sources have multiple uses. You can use them
for amplitude, frequency, and phase modulation. For pulse modulation you must
use the external 2 source. However, any given source can only be routed to one
enabled modulation at a time. If, for example, you were using the external 1
source in a frequency modulation configuration for
FM Path 1
, and then you
configured
AM Path 2
to also use the external 1 source, the signal generator would
turn off
FM Path 1
and assign the external 1 source to your
AM Path 2
configuration. Notice that for these purposes the external 1 AC-coupled source is
the same as the external 1 DC-coupled source and the external 2 AC-coupled
source is the same as the external 2 DC-coupled source.
Softkey Location: Press
AM
,
AM Source
Status after Normal Preset: INT
SCPI Commands:
[:SOURce]:AM[1]|2:SOURce?
Содержание ESG Series
Страница 3: ...ii ...
Страница 29: ...1 12 Preparing for Use Verifying Signal Generator Operation ...
Страница 43: ...2 14 Using Functions Saving and Recalling an Instrument State ...
Страница 95: ...3 52 Troubleshooting HP Sales and Service Offices ...
Страница 109: ...4 14 Front and Rear Panel Rear Panel Overview ...
Страница 111: ...5 2 Hardkey and Softkey Reference ...
Страница 135: ...5 26 Hardkey and Softkey Reference Ampl ...
Страница 137: ...5 28 Hardkey and Softkey Reference Amplitude ...
Страница 139: ...5 30 Hardkey and Softkey Reference Arrow Keys ...
Страница 141: ...5 32 Hardkey and Softkey Reference Display Contrast Keys ...
Страница 161: ...5 52 Hardkey and Softkey Reference FM ...
Страница 169: ...5 60 Hardkey and Softkey Reference Frequency ...
Страница 171: ...5 62 Hardkey and Softkey Reference Help ...
Страница 173: ...5 64 Hardkey and Softkey Reference Hold ...
Страница 175: ...5 66 Hardkey and Softkey Reference Incr Set ...
Страница 195: ...5 86 Hardkey and Softkey Reference LF Out ...
Страница 197: ...5 88 Hardkey and Softkey Reference Local ...
Страница 199: ...5 90 Hardkey and Softkey Reference Mod On Off ...
Страница 200: ...5 91 Hardkey and Softkey Reference Mode Mode This front panel key is reserved for future use ...
Страница 201: ...5 92 Hardkey and Softkey Reference Mode ...
Страница 203: ...5 94 Hardkey and Softkey Reference Numeric Keypad ...
Страница 225: ...5 116 Hardkey and Softkey Reference Power Switch ...
Страница 235: ...5 126 Hardkey and Softkey Reference Preset ...
Страница 241: ...5 132 Hardkey and Softkey Reference Pulse ...
Страница 245: ...5 136 Hardkey and Softkey Reference Recall ...
Страница 247: ...5 138 Hardkey and Softkey Reference Return ...
Страница 249: ...5 140 Hardkey and Softkey Reference RF On Off ...
Страница 255: ...5 146 Hardkey and Softkey Reference Save ...
Страница 275: ...5 166 Hardkey and Softkey Reference Sweep List ...
Страница 311: ...6 10 Options and Accessories Upgrade and Retrofit Kits ...
Страница 312: ...7 1 7 Operation This chapter is reserved for future use ...
Страница 313: ...7 2 Operation ...
Страница 322: ...8 9 Safety and Regulatory Declaration of Conformity Declaration of Conformity ...
Страница 341: ...9 18 Specifications HP ESG Series Signal Generators Specifications ...