Functional Verification: Aux Out Test
Description
The purpose of this test is to check the Aux Out port. A pulse is sent to the
Aux Out port for each zero crossing of the 10 kHz sinewave.
Test Procedure
1. Reset the AFG:
*RST;*CLS
Reset AFG and clear status registers
2. Set up the equipment as shown in Figure 2-2. Set scope Channels A
and B to 2 V/div, .02 msec/div.
3. Set up the AFG to output a 10 kHz sinewave with gating enabled:
FREQ 1E4;
Set freq to 1 MHz
:OUTP:LOAD INF
Infinite load
VOLT 4VPK
Set AFG amplitude
MARK:FEED "OUTP:ZERO"
Marker at zero crossings
INIT:IMM
Initiate
4. Verify that Channel A displays a 10 kHz sinewave. Verify that
Channel B displays a 10 kHz squarewave.
Figure 2-2. Aux Out Test Setup
Chapter 2
Verification Tests 27