Fault Isolation 4-27
The system responds by displaying the contents of the file, which, if your node has no
problems, may look like the following display:
tuesday, September 26, 19xx
2:40 pm (EDT) system startup
error totals
system startups 1
system shutdowns 0
The following display shows how the system error log stores a memory failure. Note
that “
board pair - 2
” pertains to the second group of memory board slots on the CPU
board, which are labeled 1A and 1B. The “
board - 0
” reference applies to the first
board in the pair (the board in Slot 1A). Refer to the
Identifying Defective Memory
Boards
Subsection earlier in this chapter for more information about memory board
configurations.
Wednesday, may 2, 1990
3:34:31 pm (EST) eccc error
mcsr - 00000091, physical address: FF5D8DE4 or FF5D8DEC,
( board pair - 2, board - 0, bit - 64, syndrome - 01 )
4.5.3
System Acceptance Exerciser (SAX)
SAX tests reside in the /systest directory on the system disk. These tests verify system
operation by completely exercising the system, including system options, peripherals,
and networks.
SAX includes Storage Subsystem Tests (SST), a new diagnostic for detailed testing of
storage devices, which replaces all storage tests of previous SAX releases.
You can also run SST outside of the SAX environment. When run by itself, SST pres-
ents you with a prompt-based user interface. You can also select a graphical interface.
You can run SAX tests from a system’s disk, from another disk on the network, or (if
the display is inoperative) through an SIO line to another system. For more information
about SAX tests, refer to
Using Domain Diagnostics, Volume 1
.
Содержание Apollo 9000 400dl
Страница 1: ...Servicing the HPApollo 9000 Series 400 Workstations Order No A1630 90007 Manufacturing No A1630 90607 ...
Страница 4: ...iv VCCI Class 1 ITE Equipment VCCI Class 2 ITE Equipment ...
Страница 6: ...vi ...
Страница 22: ......
Страница 26: ...1 4 Product Overview Figure 1 1 HP Apollo Model 400t or Model 400dl Workstation ...
Страница 40: ......
Страница 42: ...2 2 System Controls Figure 2 1 Model 400t and 400dl System ...
Страница 54: ...3 4 Theory of Operation Figure 3 1 Model 400t System Block Diagram ...
Страница 55: ...Theory of Operation 3 5 Figure 3 2 Model 400dl System Block Diagram ...
Страница 56: ...3 6 Theory of Operation Figure 3 3 Model 400s Standard I O System Unit Functional Block Diagram ...
Страница 57: ...Theory of Operation 3 7 Figure 3 4 Model 400s DIO II System Unit Functional Block Diagram ...
Страница 58: ...3 8 Theory of Operation Figure 3 5 Model 400s ISA System Unit Functional Block Diagram ...
Страница 70: ...3 20 Theory of Operation Figure 3 6 Model 400s System Unit Power Distribution Diagram ...
Страница 74: ...4 4 Fault Isolation Figure 4 1 Main Flowchart ...
Страница 75: ...Fault Isolation 4 5 Figure 4 1 Main Flowchart Cont ...
Страница 76: ...4 6 Fault Isolation Figure 4 2 Model 400t and 400dl System Power LED Not On ...
Страница 77: ...Fault Isolation 4 7 Figure 4 3 Model 400s System Power LED Not On ...
Страница 78: ...4 8 Fault Isolation Figure 4 4 Domain Keyboard Problems ...
Страница 79: ...Fault Isolation 4 9 Figure 4 5 Problems with Display ...
Страница 80: ...4 10 Fault Isolation Figure 4 6 Diskless Node Partnering Problems ...
Страница 81: ...Fault Isolation 4 11 Figure 4 7 Problems with Winchester Disk ...
Страница 82: ...4 12 Fault Isolation Figure 4 8 Problems While Booting ...
Страница 83: ...Fault Isolation 4 13 Figure 4 9 Node Causes Network Problems ...
Страница 86: ...4 16 Fault Isolation Figure 4 10 Diagnostic Relationships for Domain OS Compatible Mode ...
Страница 99: ...Fault Isolation 4 29 Figure 4 13 HP UX Compatible Mode Main Troubleshooting Flowchart ...
Страница 100: ...4 30 Fault Isolation Figure 4 14 HP UX Compatible Mode Boot Flowchart ...
Страница 101: ...Fault Isolation 4 31 Figure 4 14 HP UX Compatible Mode Boot Flowchart Cont ...
Страница 131: ...Fault Isolation 4 61 Figure 4 17 System Unit Cover Removal Model 400t and Model 400dl ...
Страница 132: ...4 62 Fault Isolation Figure 4 18 Power Connections Model 400t and Model 400dl ...
Страница 148: ......
Страница 151: ...FRU Removal and Replacement 5 3 Figure 5 1 System Unit Cover Removal Model 400t and 400dl ...
Страница 152: ...5 4 FRU Removal and Replacement Figure 5 2 System Components Model 400t and 400dl ...
Страница 153: ...FRU Removal and Replacement 5 5 Figure 5 3 Rear View of the Model System Unit Model 400t and 400dl ...
Страница 161: ...FRU Removal and Replacement 5 13 Figure 5 10 Disconnecting Internal Cables from the CPU Board Model 400t and 400dl ...
Страница 181: ...FRU Removal and Replacement 5 33 Figure 5 26 Model 400s Front Door Removal ...
Страница 183: ...FRU Removal and Replacement 5 35 Figure 5 27 Model 400s Bezel Removal ...
Страница 193: ...FRU Removal and Replacement 5 45 Figure 5 34 Model 400s ISA Backplane Removal ...
Страница 195: ...FRU Removal and Replacement 5 47 Figure 5 35 Model 400s ISA Card Cage Removal ...
Страница 205: ...FRU Removal and Replacement 5 57 Figure 5 40 Model 400s Memory Board Removal ...
Страница 209: ...FRU Removal and Replacement 5 61 Figure 5 43 Model 400s ISA Center Wall Removal ...
Страница 211: ...FRU Removal and Replacement 5 63 Figure 5 44 Model 400s Standard ISA Motherboard Removal ...
Страница 213: ...FRU Removal and Replacement 5 65 Figure 5 45 Model 400s 3 Slot DIO II Card Cage Removal ...
Страница 215: ...FRU Removal and Replacement 5 67 Figure 5 46 Model 400s DIO II Center Wall Removal ...
Страница 217: ...FRU Removal and Replacement 5 69 Figure 5 47 Model 400s DIO II Motherboard Removal ...
Страница 221: ...FRU Removal and Replacement 5 73 Figure 5 49 Model 400s LED Board Removal ...
Страница 234: ......
Страница 236: ...A 2 FRU Configurations Figure A 1 CPU Board Configurations ...
Страница 240: ...A 6 FRU Configurations Figure A 5 Alternate 802 5 Network Controller AT Jumper Configuration ...
Страница 282: ......