5-16
Maintenance
Reinstalling the System Software
Reinstalling the System Software
This section shows you how to reinstall the chromatic dispersion, National
Instruments 488, and remote shell software. The DAC02 and National Instru-
ments 488 software must be installed in order to run the HP 86037B. The
remote shell software must be installed in order to run the HP 86037B in
remote mode. The files necessary to install the chromatic dispersion software,
NI-488 code, and remote shell service are in the subdirectory named
Related Instructions
located under the main install directory. The file and direc-
tory structure is listed below:
\DAC02
Port95NT.exe
\NI-488
version.txt
\disk1
. . .
setup.exe
. . .
\disk2
. . .
\RSH
rsh_start.bat
rshsetup.exe
rshsvc.dll
rshsvc.exe
rshsvc.txt – Instructions for installation
To install the NI-488 code
1
Run the file
setup.exe
from the
disk1
directory
2
Click
custom installation
from the setup program
3
Click only the
driver
option. After the installation is finished, run the GPIB utility
which is found as the GPIB icon in the control panel. When the GPIB utility
window is displayed, select
OK
. When the next window is displayed, select
Yes
To install the DAC02 code
1
Run the file
Port95NT.exe
from the
DAC02
directory and click
Yes
at the prompt
Содержание 86037B
Страница 1: ...User s Guide HP 86037B Chromatic Dispersion Test System ...
Страница 31: ...2 13 Operation The Main Window Figure 2 4 Repeat Measurement Selector ...
Страница 72: ...3 16 Normalization Setting Normalization Preferences ...
Страница 94: ...4 22 Remote Control TES Parameters Main chromatic dispersion screen ...
Страница 100: ...4 28 Remote Control TES Parameters CD and Gain Measurement Settings Dialog Box ...
Страница 102: ...4 30 Remote Control TES Parameters Length Measurement Settings Dialog Box ...
Страница 104: ...4 32 Remote Control TES Parameters Normalization Settings Dialog Box ...
Страница 106: ...4 34 Remote Control TES Parameters New Normalization Button Dialog Box ...
Страница 120: ...4 48 Remote Control Output Parameters ...
Страница 158: ...5 38 Maintenance Hewlett Packard Sales and Service Offices ...
Страница 165: ...6 7 Installation Installation 2 3 4 5 1 8 7 Fan Pack 6 6 Power Distribution Assembly 1 7 Power Distribution Assembly 2 ...
Страница 170: ...6 12 Installation Installation ...
Страница 174: ...7 4 Reference Theory of Operation Figure 7 3 HP 86037B Block Diagram Options 121 and 122 ...
Страница 175: ...7 5 Reference Theory of Operation Figure 7 4 The HP 86037B Option 114 block diagram ...
Страница 190: ...7 20 Reference System Options ...
Страница 191: ...8 Specifications 8 3 Regulatory Information 8 7 Specifications and Regulatory Information ...
Страница 198: ...8 8 Specifications and Regulatory Information Regulatory Information Declaration of Conformity ...
Страница 204: ...Index 6 Index ...