•
The Y axis is the relative number of occurrences in each bucket.
•
Maximum value of the Y axis is constantly updated to reflect the number
of occurrences in the bucket that has the most occurrences, and is
displayed as "Max count."
•
The total number of states sampled for the selected label is presented as
Total count. This includes states that may be outside the user-specified
X axis range.
•
Two markers are available on the X axis to determine the range of a
bucket and number of occurrences in any bucket.
•
Choice of base for a specified label is user-definable.
State Histogram
The State Histogram mode displays states that occur
within user-defined ranges of a label. State Histogram is available on any
label defined in the Format Specification.
•
Maximum number of ranges is 11.
•
Other States included/excluded is available and displays a histogram of all
states not covered by the user-defined ranges.
•
You can tTrace All States or pattern Qualified States.
•
Total samples displays the total number of occurrences in all displayed
ranges.
•
Choice of base for specified label is user-definable.
Time Interval
The Time Interval mode displays time intervals between
user-defined start and end events.
•
Start and end events can be defined over all labels defined in the Format
Specification.
•
10 ns is the minimum sample period and time interval resolution.
•
The maximum number of time interval ranges is 8.
•
Time interval range size is 10 ns to 9,999,999 seconds.
•
Calculated statistics provides Maximum time, Minimum time, Average
time, and Total number of time intervals sampled (one time interval
defined to be a paired start/end event).
•
Auto-range feature automatically scales the eight time intervals over
maximum and minimum times using a logarithmic scale or linear scale.
•
Choice of base for labels is user-definable.
System Performance Analysis (SPA) Software
What is System Performance Analysis?
8-5
Содержание 1660CS
Страница 5: ...Introduction iv ...
Страница 16: ...1 Logic Analyzer Overview ...
Страница 24: ...2 Connecting Peripherals ...
Страница 33: ...2 10 ...
Страница 34: ...3 Using the Logic Analyzer ...
Страница 55: ...3 22 ...
Страница 56: ...4 Using the Trigger Menu ...
Страница 75: ...4 20 ...
Страница 76: ...5 Triggering Examples ...
Страница 109: ...5 34 ...
Страница 110: ...6 File Management ...
Страница 114: ...Saving the system configuration for programmatic control File Management To save a configuration 6 5 ...
Страница 119: ...6 10 ...
Страница 120: ...7 Reference ...
Страница 221: ...7 102 ...
Страница 222: ...8 System Performance Analysis SPA Software ...
Страница 241: ...SPA Time Interval System Performance Analysis SPA Software SPA measurement processes 8 20 ...
Страница 252: ...9 Concepts ...
Страница 273: ...HP 1660CS series analyzer theory HP 1660C CS logic analyzer The Analyzer Hardware HP 1660CS series analyzer theory 9 22 ...
Страница 279: ...Oscilloscope board theory Oscilloscope board The Analyzer Hardware Oscilloscope board theory 9 28 ...
Страница 284: ...10 Troubleshooting ...
Страница 298: ...11 Specifications ...
Страница 311: ...11 14 ...
Страница 312: ...12 Operator s Service ...
Страница 324: ...Troubleshooting Flowchart 2 Troubleshooting To use the flowcharts 12 13 ...
Страница 337: ...Glossary 4 ...