Global timers 1 and 2
In addition to the resource terms available, there are two global timers
available. Each timer can be started, paused, continued, or stopped, from
any sequence level except the first.
Assigning resource term names and values
The Terms field identifies the list of available resource terms within the
analyzer. A resource term can be assigned to only one machine at a time.
The resource term names (a
−
j, Edge1, Edge2, Range1, Range2) are default
names that can be changed. You assign values in the following two ways:
•
Using Preset Values
•
Assigning Bit by Bit
Changing resource properties
When any of the individual term fields
are selected, a configuration pop-up appears. Use this pop-up menu to
quickly set the resource term to a preset value.
Using Preset Values
Assign
Assign toggles which machine the term is assigned to. All of the
available resource terms except the Edge terms can be assigned to any
analyzer. However, a term can only be assigned to one analyzer at a time.
Rename
Rename lets you change the term name. This function works
for all terms.
Clear (=X)
Clear sets the terms to their broadest possible meaning. For
terms a
−
j, the assignment field is set to all Xs (don’t cares). For Range 1
and 2, the boundaries are set to the maximum and minimum values. For
Timers 1 and 2, the assignment field is set to a minimum time of 400 ns.
For Edge 1 and 2, the assignment field is set to don’t cares.
Set (=1)
In terms a
−
j, the assignment field is set to its maximum
value, with all bits set to 1. This option is not available for the Range,
Timer, and Edge terms.
Reset (=0)
In terms a
−
j, the assignment field is set to its minimum
value, with all bits set to 0. This option is not available for the Range,
Timer, and Edge terms.
The Analyzer Trigger Menu
Resource terms
7-52
Содержание 1660CS
Страница 5: ...Introduction iv ...
Страница 16: ...1 Logic Analyzer Overview ...
Страница 24: ...2 Connecting Peripherals ...
Страница 33: ...2 10 ...
Страница 34: ...3 Using the Logic Analyzer ...
Страница 55: ...3 22 ...
Страница 56: ...4 Using the Trigger Menu ...
Страница 75: ...4 20 ...
Страница 76: ...5 Triggering Examples ...
Страница 109: ...5 34 ...
Страница 110: ...6 File Management ...
Страница 114: ...Saving the system configuration for programmatic control File Management To save a configuration 6 5 ...
Страница 119: ...6 10 ...
Страница 120: ...7 Reference ...
Страница 221: ...7 102 ...
Страница 222: ...8 System Performance Analysis SPA Software ...
Страница 241: ...SPA Time Interval System Performance Analysis SPA Software SPA measurement processes 8 20 ...
Страница 252: ...9 Concepts ...
Страница 273: ...HP 1660CS series analyzer theory HP 1660C CS logic analyzer The Analyzer Hardware HP 1660CS series analyzer theory 9 22 ...
Страница 279: ...Oscilloscope board theory Oscilloscope board The Analyzer Hardware Oscilloscope board theory 9 28 ...
Страница 284: ...10 Troubleshooting ...
Страница 298: ...11 Specifications ...
Страница 311: ...11 14 ...
Страница 312: ...12 Operator s Service ...
Страница 324: ...Troubleshooting Flowchart 2 Troubleshooting To use the flowcharts 12 13 ...
Страница 337: ...Glossary 4 ...