Measurement algorithms
Frequency (Freq)
The frequency of the first complete cycle displayed
is measured using the 50% levels.
If the first edge on the display is rising, then
Freq =
1
t
rising
edge
2
−
t
rising
edge
1
If the first edge on the display is falling, then
Freq
=
1
t
falling
edge
2
−
t
falling
edge
1
Period
The period is measured at the 50% voltage level of the waveform.
If the first edge on the display is rising, then
Period
=
t
rising
edge
2
−
t
rising
edge
1
If the first edge on the display is falling, then
Period
=
t
falling
edge
2
−
t
falling
edge
1
Peak-to-Peak Voltage (Vp_p)
The maximum and minimum voltages
for the selected source are measured:
Vp_p
=
V
maximum
−
V
minimum
,
where V
maximum
and V
minimum
are the maximum and minimum voltages
present on the selected source.
Positive Pulse Width (+Width)
Pulse width is measured at the 50%
voltage level.
If the first edge on the display is rising, then
+Width
=
t
falling
edge
1
−
t
rising
edg e
1
If the first edge on the display is falling, then
+Width
=
t
falling
edge
2
−
t
rising
edg e
1
Negative Pulse Width (
−
Width)
Negative pulse width is the width of
the first negative pulse on screen using the 50% levels.
If the first edge on the display is rising, then
−
Width
=
t
rising
edge
2
−
t
falling
edg e
1
If the first edge on the display is falling, then
−
Width
=
t
rising
edge
1
−
t
falling
edg e
1
The Scope Auto Measure Menu
Automatic measurement algorithms
7-100
Содержание 1660CS
Страница 5: ...Introduction iv ...
Страница 16: ...1 Logic Analyzer Overview ...
Страница 24: ...2 Connecting Peripherals ...
Страница 33: ...2 10 ...
Страница 34: ...3 Using the Logic Analyzer ...
Страница 55: ...3 22 ...
Страница 56: ...4 Using the Trigger Menu ...
Страница 75: ...4 20 ...
Страница 76: ...5 Triggering Examples ...
Страница 109: ...5 34 ...
Страница 110: ...6 File Management ...
Страница 114: ...Saving the system configuration for programmatic control File Management To save a configuration 6 5 ...
Страница 119: ...6 10 ...
Страница 120: ...7 Reference ...
Страница 221: ...7 102 ...
Страница 222: ...8 System Performance Analysis SPA Software ...
Страница 241: ...SPA Time Interval System Performance Analysis SPA Software SPA measurement processes 8 20 ...
Страница 252: ...9 Concepts ...
Страница 273: ...HP 1660CS series analyzer theory HP 1660C CS logic analyzer The Analyzer Hardware HP 1660CS series analyzer theory 9 22 ...
Страница 279: ...Oscilloscope board theory Oscilloscope board The Analyzer Hardware Oscilloscope board theory 9 28 ...
Страница 284: ...10 Troubleshooting ...
Страница 298: ...11 Specifications ...
Страница 311: ...11 14 ...
Страница 312: ...12 Operator s Service ...
Страница 324: ...Troubleshooting Flowchart 2 Troubleshooting To use the flowcharts 12 13 ...
Страница 337: ...Glossary 4 ...