6.1.6 hydraulic integration
BioLyt (50-160)
Pellet boiler with
-
energy buffer storage tank (> 20 l/kW)
-
calorifier
- 1-... mixer circuit(s)
Hydraulic schematic BCDE010
1
A
B
D
E
C
F
2
3
4
5
6
7
8
9
1
2
3
4
5
6
7
8
9
A
B
D
E
C
F
BCDE010.dwg
Achtung !
Für die Installation muss das anlagenbezogene Schema verwendet werden!
Attention!
This is just a schematic. For installation please use the detail-plan!
Attenzione!
Per la messa in opera, utilizzare le schema dettagliato!
Attention!
Pour la réalisation pratique de l'installation, il faut utiliser le schéma détaillé!
Datum:
Datei:
Version:
Blatt:
Hydr.
Verbindungshinweise /
Notice / Nota / Remarque:
1
BCDE010
Name:
4.3
HATI
29.11.2016
T
T
T
T
YKR
P
RLF
PF-A
TTE-PS
TTE-FE
HK
TTE-WEZ
AF
RBM
TTE-GW
KKP
T
UPA
PF1
PF2
Option/opzione
2. Puffer
2. Buffer
2. Accumulatore
2. Accumulateur
BioLyt
³
50
MK1
T
T
VF1
YK1
SLP
T
T
B1.1
MK2
T
T
B1.2
VF2
YK2
Option / Opzione
PF2
T
SF2
SF
TTE-WEZ
TopTronic
®
E basic module heat generator (installed)
TTE-PS
TopTronic
®
E buffer module
VF1
Flow temperature sensor 1
B1.1
Flow temperature guard (if required)
MK1
Pump mixer circuit 1
YK1
Actuator mixer 1
UPA
Actuator, start load relief (single-wire control)
AF
Outdoor sensor
SF
Calorifier sensor
SF2
Calorifier sensor 2
RLF
Return sensor
PF1
Buffer sensor 1
PF2
Buffer sensor 2
PF-A
Buffer sensor automatic unit
SLP
Calorifier charging pump
KKP
Boiler circuit pump
Option
RBM
TopTronic
®
E room control module
TTE-GW
TopTronic
®
E Gateway
TTE-FE HK TopTronic
®
E module expansion heating circuit
VF2
Flow temperature sensor 2
B1.2
Flow temperature guard (if required)
MK2
Pump mixer circuit 2
YK2
Actuator mixer 2
NOTICE
- This hydraulic schematic is a principle
sche matic. It does not contain all details for
in stallation. The installation must be done
ac cording to local conditions, di men sioning
and regulations
-
For
underfloor
heating,
a
flow
tempe ra tu re monitor must be built in.
-
Shut-off devices to the safety val
-
ve (pres
surised expansion tank, sa-
fety valve, etc.) are to safe against
uninten ded closing!
- Mount bags to prevent single pipe
gravity circulation.
43
4 214 852 / 01
InSTALLATIOn