3.9
Fitting the casing BioL
yt
(50-75)
Attachment set
A, C
NOTICE
Before proceeding
with the installation of
the
casing, make sure that
all the cables and
electrical
connections
to
the
automatic
firing
device have been fitted.
23.
Fit the thermal insulation mats (30, Fig. 20) and (28, 28a, Fig. 13).
24.
Slide the side walls
(31) into the plinth rails and hook into the slots of the attachment bracket
above.
25.
Hook
the
controller
box
(32)
on
the
right
or
left
side
wall
(position
depending
on
the
automatic
firing
device).
Mount 2 special
screws M4x8 with
nuts M4 in
the casing
previously
. Additionally
secure
the controller
box with 2 self-tapping
screws Ø 3.5 mm at the top. Route the temperature sensor
for the safety temperature
limiter (STB) to the back of the boiler
and insert it into the immersion
sleeve
(with
boiler
and
flow
temperature
sensors)
and
secure
with
the
capillary
support
spring.
Connect safety temperature limiter by fitting flat plug onto mounting tongues 1 and 2.
26.
Loosely
fit protection plate (33a, Fig. 18 and Fig. 19) to the left and right top side wall
(33, Fig. 18
and Fig. 20). Hook in the side walls. Position and adjust the protection plates and attach to the pellet
hopper
(serrated
washer
+ washer
must be
used
for the earth
connection).
Attach speed
nuts (C-clips, 33b) (C).
27.
Mount the top sections of the rear wall (34, 34a) using self-tapping screws (A).
28.
Mount the middle section of the rear wall (35) using self-tapping screws (A).
29.
Take
off
sight
glass.
Mount
the
bottom
section
of
the
rear
wall
(36)
using
self-tapping
screws
(A).
Mount the ground cable (on the
AA
T cable) in the position
s provided
(on left or right side of the
recess) using self-tapping screws. Fit the ash discharge motor cover (36a). Refit the sight glass.
30.
Insert the rear cover (37).
31.
Fit the front cover (38) (must be fitted before installing the discharge hoses).
32.
Insert
the right
and left
burner cover at
the
bottom
(39, 39a) on the
screw heads provided and
press against the casing side panels at the top.
33.
Hook in the front burner cover (40) at the side and screw to the protection plates (33a) at the top. Hook in the front hood (40a) (pay attention to the slots).
34.
Screw the cover plate (41, 41a) to the rear side walls (A).
35.
Installation of no. 42, see chapter 3.10.
NOTICE
For
34,
34a, 35,
36 and 36a (Fig.
a
ser
-
rated washer must
be used for
one of
the
self-tapping
screws (Fig. 37, detail X) (earth
connection).
Fig. 18
Fig. 19
4212946
32-BioLyt (50-75) / grma / 06.06.2014 M 1 : 1
33
33a
33b
NOTICE
Note: Insert
cover (38) before mounting the
suction hoses.
18
4 214 852 / 01
ASSEMBLy BIOLyT (50-75)
Содержание BioLyt 100