2.1.3 Set-up of UltraGas
®
2 (125,150)
!
WARNING
Tip hazard during set-up.
There is a danger of the boiler tilting over
when moving it on the pallet or when remov-
ing the pallet.
• Carry out these works with great care.
1. Remove climbing aid (1).
2
1
Fig. 03
2. Turn the boiler on the pallet (2) through 45°.
3. Push the boiler so that 3 boiler feet (3) can be mount-
ed (2 feet on the front and 1 foot on the rear).
3
3
3
Fig. 04
4. Raise the boiler with the pallet (e.g. using a lift truck).
5. Pre-assemble 3 boiler feet (3) (tighten screws by
hand).
6. Carefully lower the boiler again (danger of tipping over)
- The boiler remains on 3 feet.
7. Remove the pallet from under the boiler.
8.
Mount the 4th boiler foot (4).
4
Fig. 05
9.
Tighten the screws of all 4 feet.
!
WARNING
Tip hazard.
Unscrew the feet max. 80 mm.