A power cord is not supplied with the appliance, but the hob is
equipped with a terminal block which enables you to choose the
correct connection for the particular power supply.
Installing a domestic appliance can be a complicated operation which if not carried out correctly, can seriously affect consumer
safety. It is for this reason that the task should be undertaken by a professionally qualified person who will carry it out in
accordance with the technical regulations in force. In the event that this advice is ignored and the installation is carried out
by an unqualified person, the manufacturer declines all responsibility for any technical failure of the product whether or not
it results in damage to goods or injury to individuals.
2 GB
BUILT-IN
The furniture in which your hob will be installed and all adjacent
furniture, should be made from materials that can withstand high
temperatures. In addition, all decorative laminates should be fixed
with heat-resistant glue.
Installation:
• A watertight seal is supplied with the hob.
Before fitting:
- turn the hob upside down, with the glass surface facing downwards.
Make sure the glass is protected.
- fit the seal round the hob.
- make sure that it is correctly fitted to avoid any leakage into the
supporting cabinet.
• Leave a gap of at least 5 cm between the appliance and the
vertical sides of the adjacent furniture.
• If, when installing the hob, the lower hob face is adjacent to an
area normally accessible when handling or cleaning, fit a partition
1 cm below the base of the hob to avoid any risk of scorching
or damage.
INSTALLATION
"The installation must conform to the standard directives."
The manufacturer declines all responsibility for any damage that
may be caused by unsuitable or unreasonable use.
Warning :
• Always check before any electrical operation, the supply tension
shown on the electricity meter, the adjustment of the circuit-
breaker, the continuity of the connection to earth to the installation
and that the fuse is suitable.
• The electrical connection to the installation should be made via
a socket with a plug with earth, or via an omnipole cut-out switch
with an opening gap of at least 3 mm.
If the appliance has a socket outlet, it must be installed so that
the socket outlet is accessible.
• The yellow/green wire of the power supply cable must be
connected to the earth of both power supply and appliance
terminals.
• The manufacturer cannot be held responsible for any accidents
resulting from the use of an appliance which is not connected
to earth, or with a faulty earth connection continuity.
• Any queries regarding the power supply cord should be referred
to After Sales Service or a qualified technician.
ELECTRICAL CONNECTION
min 10 mm
Sp da 25 a 45 mm
Accessible
space
Seal
Hob
min 70 cm
min 15 cm
min 5,5 cm
10 mm
mini
50 mm
Opening
500 X 50
Opening
500 X 10
It is forbidden
to fit the hob
above a non-
ventilated oven
To proceed with the connection, you must adhere to the following
instructions.
• Before making the connection, make sure that the installation
is protected by a suitable fuse, see table, and that it is fitted
with wires of a large enough section to supply the appliance
normally.
• Choose the supply cord in accordance with the recommendations
in the table.
• Turn the hob, with the glass side against the worktop,
providing
you have protected the glass !
CONNECTION TO THE TERMINALS ON THE TERMINAL BLOCK:
ELECTRICAL CONNECTION
3 G 2,5 mm
2
H05RR-F,
H05VV-F,
H05V2V2-F
3 G 2,5 mm
2
H05RR-F,
H05VV-F,
H05V2V2-F
4 G 2,5 mm
2
H05RR-F,
H05VV-F,
H05V2V2-F
4 G 2,5 mm
2
H05RR-F,
H05VV-F,
H05V2V2-F
5 G 1,5 mm
2
H05RR-F,
H05VV-F,
H05V2V2-F
Monophase
220-240V~
Two phases
220-240V2~
Two phases
220-415V2N~
Three phases
220-240V3~
Three phases
380-415V3N~
25 A
25 A
25 A
25 A
16 A
FUSE
CABLE
AREA
TYPE
2 Phase
shunt 1-2
shunt
2-3
5 Neutral
shunt
4-5
T Earth
CONNEC-
TION TO
THE
TERMIMAL
BLOCK
2 Phase
shun 1-2
shunt
2-3
5 Phase
shunt
4-5
T Earth
1 Phase
3 Phase
shunt 2-3
5 Neutral
shunt
4-5
T Earth
1 Phase
shunt
1-2
3 Phase
shunt
3-4
5 Phase
T Earth
1 Phase
2 Phase
3 Phase
5 Neutral
shunt 4-5
T Earth
• Open the cover in the following
sequence:
• find the two tabs located on the
sides,
• put the blade of a flat screw-
driver in front of each tab, push
in and press,
• remove the cover.
• Connect the power supply cable:
• comply with the information of the table and the markings
on the terminal board and install the shunts (the shunts, inserted
in the terminal board, make a bridge between two terminals),
• strip the end of each
conductor and attach
them to the terminals,
complying with the infor-
mation given in the table,
• unscrew the cable clamp,
• pass the lead through the
cable clamp.
When you have finished
the connection operation
to the appliance terminals,
tighten the cable clamp and
close the cover.
Note:
make sure the terminal board screws are tight.
SHUNT
L2
L3