52
| English
9 .2 OTHER FAULTS
Malfunction
Possible cause
Remedy
Setting tool does not react
b.) No battery inserted
c.) Battery discharged
d.) The tool is locked
a.) Insert battery.
b.) Charge the battery.
c.) Unlock tool, see chapter 3.3.
The LED for illumination of
the riveting point does not
come on or goes out again
immediately
a.) Standby time for the LED foot
light set to “0” or a very short
time
b.) Foot LED defective
a.) Reset the standby time.
b.) Send the setting tool to HONSEL
Service, see chapter 5.4.
Fastener not set correctly
a.) Force set too high or too low
b.) Stroke set too high or too low
Set up the setting tool again, see
Fastener not set correctly
Spin on time too short
Set up the setting tool again, see
Fastener is not unscrewed
correctly
Spindle out time too short
Adjust the spindle out time in menu
Expert / Spindle Settings / Set
spindle out time
.
Spin on mode does not
trigger spindle out
a.) Setting tool switched off /
battery discharged
b.) Spin on mode set incorrectly
c.) Threaded mandrel or
threaded sleeve blocked
d.) Trigger defective
a.) Switch on the setting tool / replace
the battery.
b.) Check spin on mode in menu
Expert / Work Mode
.
c.) Press the trigger once without a
fastener.
d.) Send the setting tool to HONSEL
Service, see chapter 5.4.
After switching on, the
setting tool does not
perform a calibration run
Software error
a.) Remove the battery and insert
again after 2 seconds.
b.) Send the setting tool to HONSEL
Service, see chapter 5.4.
The protruding threaded
mandrel or bolt length
changes
Software error
a.) Remove the battery and insert
again after 2 seconds.
b.) Send the setting tool to HONSEL
Service, see chapter 5.4.