English |
43
Fastener
material
Fastener diameter
M3
M4
M5
M6
M8
M10
M12
Aluminium
5
7
8
14 22 24 25
Steel
7
10 11 18 23 33 57
Stainless steel 9
12 15 32 45 70 82
If the value selected from the table leads to a poor
setting result during the first setup, increase the
setting step by step with the values given below
until an optimum setting result is obtained.
Colour range for the
setting value
Gradual adjustment
Light grey
0.1 to 0.2
White
0.2 to 0.5
Dark grey
0.5 to 1.0
3 .5 .3 .2 Setting values for stroke
The stroke values given are setting
values without units and do not
correspond to the actual stroke
executed in mm.
The same setting values for the
strokes apply for all fastener
materials.
Fastener diameter
M3
M4
M5
M6
M8
M10
M12
1.5
2.0
2.5
3.5
4.5
5.5
6.5
Gradual adjustment for all stroke setting values:
0.1 to 0.2
3 .5 .3 .3 Assess setting result
See figure d, Assessment of setting result
No .
Designation
1
Force / stroke value too low
2
Force / stroke value too high
3
Optimum force / stroke value
3 .6 CONFIGURE THE SETTING TOOL /
CHANGE SETTINGS
3 .6 .1 Overview of functions / setting
options
Function
Description / setting
options
How?
Riveting point
illumination
time
Input of a time in
seconds
The set illumination
time is the number
of seconds for which
the riveting point
is illuminated after
pressing the trigger
or inserting the
battery.
Standby time Input of a time in
seconds
The standby time
indicates the number
of seconds after
which the display
goes dark.
Language
• DE (=Deutsch)
• EN (=English)
• FR (=Français)
• IT (=Italiano)
• ES (=Español)
• PT (=Português)
Counter
• ON
• OFF
• Reset
The counter shows
how many fasteners
have been set since
switching on or
resetting the counter.
Warning
sounds
• ON
• OFF
Key sounds
• ON
• OFF
Factory
settings
The setting tool can
be reset to the factory
settings.
For factory setting
values, see