38. If the memory cell is already occupied, the text
File already exists! Overwrite?
and a choice
between
Yes
and
No
appears on the screen.
39. Note the following data and store together with
the setting tool:
• Memory cell number
• Set force / stroke value
• Set spin on mode
All the settings for the setting tool,
e.g. also the set language or the
sound settings, are stored under the
selected memory cell number!
40. If necessary, select
Back
on the screen until
the
Rivdom eVNG Main
menu is displayed.
41. Navigate to
Exit
using the arrow keys.
42. Confirm the selection with the OK key.
»
The unlocked starting mask / working
mask appears on the screen.
»
The setting tool is ready for operation.
3 .5 .2 Adjust stored force / stroke values
The configuration is stored during
the new setup of the setting tool,
Precondition:
• The desired threaded mandrel or threaded
sleeve and the desired nosepiece are fitted,
• There is a drill hole for the fastener in the part.
• The setting tool is unlocked, see chapter 3.3.
1. Insert the battery into the setting tool.
2. Press the trigger briefly.
»
The unlocked starting mask / working
mask appears on the screen.
3. Hold the OK key pressed for 2 seconds.
»
The
Enter PIN
keypad appears on the
screen.
4. Enter the PIN using the arrow keys.
5. Confirm the selection with the OK key.
»
The
Rivdom eVNG Main
menu appears on
the screen.
6. Select menu item
Setup
using the arrow keys.
7. Select menu item
Adjust and Store
using the
arrow keys.
»
The menu
Adjust
appears on the screen.
»
Current force
or
Current stroke
displays the
currently set value.
8. Navigate to the input box
New force
or
New
stroke
using the arrow keys.
9. Confirm the selection with the OK key.
10. Enter a value, observing the settings and
setting instructions from chapter 3.5.3, using
the arrow keys.
Observe settings and further setting
instructions from chapter 3.5.3.
11. Confirm the selection with the OK key.
12. Save the changes under the desired memory
cell number.
13. Note the following data and store together with
the setting tool:
• Memory cell number
• Set force / stroke value
• Set spin on mode
All the settings for the setting tool,
e.g. also the set language or the
sound settings, are stored under the
selected memory cell number!
14. If necessary, select
Back
on the screen until
the
Rivdom eVNG Main
menu is displayed.
15. Navigate to
Exit
using the arrow keys.
16. Confirm the selection with the OK key.
»
The unlocked starting mask / working
mask appears on the screen.
»
The setting tool is ready for operation.
3 .5 .3 Setting instructions for force and
stroke
The setting values given are only
guide values. If in doubt, always
start with a lower value. The
optimum setting value should be
approached step by step until an
optimum setting result is obtained,
3 .5 .3 .1 Setting values for force
The force values given are setting
values without units and do not
correspond to the actual force
exerted in kN.
If a force value of less than 6 is
entered, the setting tool prompts
you to also enter a stroke value.